OSHA Inspection: DDS MECHANICAL PLUMBING & HEATING CORP.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of DDS MECHANICAL PLUMBING & HEATING CORP. in 317 HUMBOLDT ST., BROOKLYN, NY 11211 (NAICS 238220). OSHA activity number 341119543.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch DDS Mechanical Plumbing & Heating Corp. — free Get an email when a new federal OSHA severe-injury report for DDS Mechanical Plumbing & Heating Corp. is published. One employer, no account, unsubscribe in one click.
Site address
317 HUMBOLDT ST.
City
BROOKLYN
State
NY
ZIP
11211
Mailing
38-32 54TH ST., WOODSIDE, NY 11377
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
30
Ownership type
A

1 citation on file for this inspection.

1926.1052 B01

Other-than-serious 1 instance 2 exposed
Issued
Jan 20, 2016
Abate by
Jan 26, 2016
Penalty
Initial $3,500 · Current $1,750 Reduced
29 CFR 1926.1052(b)(1): Foot traffic was not prohibited on stairways where the treads and/or landings of pan stairs were to be filled in with concrete or other material at a later date and stairs were not temporarily fitted with wood or other solid material at least to the top edge of each pan.    a) Worksite, 317 Humboldt St. Brooklyn NY - Employees were gaining access to the work area by using a newly installed stairway that had not yet been filled with concrete; on or about 12/14/15.     Note:  The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (O) $1750
  • — Z (S) $3500

View DDS Mechanical Plumbing & Heating Corp.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341119543.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.