Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: DAVID MARCOS GARCIA DBA MARCOS ROOFING

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DAVID MARCOS GARCIA DBA MARCOS ROOFING in DOWNING COURT NO. 1 410 TAYLOR STREET, JACKSON, MS 39216 (NAICS 238160). OSHA activity number 341121127.

Watch David Marcos Garcia DBA Marcos Roofing — free Get an email when a new federal OSHA severe-injury report for David Marcos Garcia DBA Marcos Roofing is published. One employer, no account, unsubscribe in one click.
Site address
DOWNING COURT NO. 1 410 TAYLOR STREET
City
JACKSON
State
MS
ZIP
39216
Mailing
2964 SOUTH PERKINS ROAD, MEMPHIS, TN 38118
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
3
Ownership type
A

3 citations on file for this inspection.

1926.501 B01

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $3080.00 · Current $3080.00
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems with toeboards, safety net systems or personal fall arrest systems.  (a)  Downing Court Apartment Building No. 1 - On or about December 9, 2015, employees accessing ladders between floors and the roof from the second and third floor balconies of Building #1 were exposed to falls to the ground of 10 feet 9 1/4 inches and 21 feet 6 1/2 inches respectively due to the absence of standard guardrails along the unguarded, open-sided proposed balconies of the second and third floors.
Recent events (1)
  • — Z (S) $3080

1926.501 B11

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $3080.00 · Current $3080.00
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems or personal fall arrest systems:  (a)  Downing Court Apartment Building No. 1 - On or about December 9, 2015, employees installing roofing felt and shingles on a steep-sloped roof (6:12 slope) located 30 feet 8.5 inches above the ground were not protected from falling by approved personal fall arrest system(s).  Employees were wearing rock-climbing waist harnesses and occasionally tethering to a small diameter lifeline without utilizing shock-absorbing lanyards as they moved about the roof.
Recent events (1)
  • — Z (S) $3080

1926.1053 B01

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $3080.00 · Current $3080.00
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:  (a)  Downing Court Building No. 1 - On or about December 9, 2015 three employees accessing the roof from a 12 foot aluminum extension ladder situated on the east end of the third floor balcony of Building #1 were exposed to falls to the ground of 21 1/2 to 30 1/2 feet due to the top of the ladder only extending about 1 foot above the upper landing, instead of at least 3 feet above the upper landing.  It was secured against displacement.