DES PLAINES, IL —
OSHA Inspection: UNITED MASONRY CONTRACTORS INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of UNITED MASONRY CONTRACTORS INC. in 714 LEE ST., DES PLAINES, IL 60016 (NAICS 238140). OSHA activity number 341123743.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- UNITED MASONRY CONTRACTORS INC.
- Site address
- 714 LEE ST.
- City
- DES PLAINES
- State
- IL
- ZIP
- 60016
- Mailing
- PO BOX 5248, WHEATON, IL 60189
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 10
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.501 B01
- Issued
- Mar 2, 2016
- Abate by
- Mar 8, 2016
- Penalty
- Initial $2,800 · Current $1,600 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a) Employees engaged in masonry work were not protected from falling, while working along the edge of the roof approximately 30 feet above the ground. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $1600
- — Z (S) $2800
1926.501 B04 I
- Issued
- Mar 2, 2016
- Abate by
- Mar 8, 2016
- Penalty
- Initial $2,000 · Current $1,100 Reduced
General-duty citation text
29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights) more than 6 feet (1.8 m) above lower levels by personal fall arrest systems, covers or guardrail systems erected around such holes: a) Employees were not protected from the hazard of falling approximately 20 feet to the lower level while performing masonry work around unguarded skylights. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (S) $1100
- — Z (S) $2000
1926.502 D08
- Issued
- Mar 2, 2016
- Abate by
- Mar 8, 2016
- Penalty
- Initial $2,000 · Current $1,100 Reduced
General-duty citation text
29 CFR 1926.502(d)(8): Horizontal lifelines were not designed, installed, and used under the supervision of a qualified person, as part of a complete personal fall arrest system, which maintained a safety factor of at least two: a) The employer did not ensure that the horizontal lifeline provided to employees as a part of a complete personal fall arrest system during masonry work was designed, installed and used under the supervision of a qualified person. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $1100
- — Z (S) $2000
1926.502 D15
- Issued
- Mar 2, 2016
- Abate by
- Mar 8, 2016
- Penalty
- Initial $2,000 · Current $1,100 Reduced
General-duty citation text
29 CFR 1926.502(d)(15): Anchorage used for attachment for personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached nor was it designed, installed and used as follows: As part of a complete personal fall arrest system which maintains a safety factor of at least two; and under the supervision of a qualified person: a) The employer did not ensure that the anchorage used by employees as an attachment point for personal fall arrest system was capable of supporting at least 5,000 pound per employee attached to it. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $1100
- — Z (S) $2000
1926.503 A01
- Issued
- Mar 2, 2016
- Penalty
- Initial $2,000 · Current $1,100 Reduced
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee who might be exposed to fall hazards: a) Employer did not provide training to each employee in order to recognize hazards associated with working at an elevation and to understand procedures to control or minimize those hazards. No abatement certification or documentation is required for this item.
Recent events (2)
- — I (S) $1100
- — Z (S) $2000
1926.502 D18
- Issued
- Mar 2, 2016
- Abate by
- Mar 8, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(d)(18): Personal fall arrest system components were used to hoist material: a) Employees engaged in masonry work were using lifelines that they were connected to for the purpose of hoisting building material to the roof. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 238140)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341123743.