RONKONKOMA, NY —
OSHA Inspection: AG LIGHT AND SOUND INC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of AG LIGHT AND SOUND INC in 151 DOMINION BLVD, UNIT-A102, RONKONKOMA, NY 11779 (NAICS 332312). OSHA activity number 341126555.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AG LIGHT AND SOUND INC
- Site address
- 151 DOMINION BLVD, UNIT-A102
- City
- RONKONKOMA
- State
- NY
- ZIP
- 11779
- Mailing
- 6755 SPEEDWAY BLVD, LAS VEGAS, NV 89115
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 39
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.212 A03 II
- Issued
- Feb 3, 2016
- Abate by
- Mar 1, 2016
- Penalty
- Initial $4,900 · Current $4,900
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): (a)Worksite, 151 Dominion Blvd, Ronkonkoma : A guard was not used to protect employees from the point of operation of the GEKA Shear Machine (Model #2004 / Serial #11053); on or about 12/8/15. Note: In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Recent events (1)
- — Z (S) $4900
1910.303 B01
- Issued
- Feb 3, 2016
- Abate by
- Mar 1, 2016
- Penalty
- Initial $1,890 · Current $1,890
General-duty citation text
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees: a) Worksite, 151 Dominion Blvd, Ronkonkoma: The outer electrical insulation of the extension cord used to power Wet/Dry Vacuum Cleaner and Air Compressor was damaged; on or about 12/15/15. NOTE: The employer is required to provide abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (1)
- — Z (S) $1890
1910.305 B02 I
- Issued
- Feb 3, 2016
- Abate by
- Mar 1, 2016
- Penalty
- Initial $3,500 · Current $3,500
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: a) Worksite, 151 Dominion Blvd, Ronkonkoma, NY: A cover was not provided for electric outlet that powers Air compressor and Wet/Dry Vacuum, exposing employees to live electrical parts; on or about 12/15/15. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (1)
- — Z (S) $3500
More inspections at AG Light and Sound INC
View AG Light and Sound INC's full OSHA safety record →
More inspections in this industry (NAICS 332312)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341126555.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.