Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NEW ENERGY BUILDERS OF COLORADO, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of NEW ENERGY BUILDERS OF COLORADO, LLC in 8501 W. BOWLES AVE, LITTLETON, CO 80123 (NAICS 238160). OSHA activity number 341126704.

Watch NEW Energy Builders OF Colorado, LLC — free Get an email when a new federal OSHA severe-injury report for NEW Energy Builders OF Colorado, LLC is published. One employer, no account, unsubscribe in one click.
Site address
8501 W. BOWLES AVE
City
LITTLETON
State
CO
ZIP
80123
Mailing
549 IOLA STREET, AURORA, CO 80010
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
1
Ownership type
A

2 citations on file for this inspection.

1926.501 B10

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 13, 2016
Abate by
Jan 26, 2016
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system.  Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system.      a) On or about December 11, 2015, employees were exposed to falls greater than 6 feet while they were installing metal roofing materials on the roof of a commercial building, without the benefit of a fall protection system being in place.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1926.1053 B08

Other-than-serious 1 instance 9 exposed
Issued
Jan 13, 2016
Abate by
Jan 26, 2016
Penalty
Initial $400 · Current $200 Reduced
29 CFR 1926.1053(b)(8): Ladders placed in a location where they could be displaced by workplace activities or traffic, such as in passageways, doorways, or driveways, were not secured to prevent accidental displacement, nor was a barricade used to keep the activities or traffic away from the ladder.       a). On or about December 11, 2015, employees were exposed to falls hazards created by the ladder they were utilizing to access the roof of a commercial building was placed in a area of high pedestrian traffic, without being secured to prevent accidental displacement nor were barricades placed around the ladder to keep traffic away.
Recent events (2)
  • — I (O) $200
  • — Z (O) $400

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341126704.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.