ROCHESTER, NY —
OSHA Inspection: OLYMPIC CONSTRUCTION OF ROCHESTER, NY INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of OLYMPIC CONSTRUCTION OF ROCHESTER, NY INC in 1545 MT. READ BOULEVARD, ROCHESTER, NY 14606 (NAICS 238160). OSHA activity number 341126936.
Where did this inspection happen?
- Establishment
- OLYMPIC CONSTRUCTION OF ROCHESTER, NY INC
- Site address
- 1545 MT. READ BOULEVARD
- City
- ROCHESTER
- State
- NY
- ZIP
- 14606
- Mailing
- 95 RODESSA ROAD, ROCHESTER, NY 14616
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 5
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B01
- Issued
- Penalty
- Initial $2800.00 · Current $2300.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. a) On or about 12/16/15, at AVI Foodsystems, located on 1545 Mount Read Boulevard, in Rochester, New York, employees were working on surfaces 10 feet above a roof landing with unprotected sides, and were not provided with fall protection. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $2300
- — Z (S) $2800
1926.1053 B01
- Issued
- Penalty
- Initial $1360.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: (a) On or about 12/16/15, at AVI Foodsystems, located on 1545 Mount Read Boulevard, in Rochester, New York, a portable extension ladder in use was not positioned so that the side rails extended at least 3 feet above the access level. The ladder was not tied off at the top and the access point was 15 feet above the lower surface. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (S) $1360
More inspections in this industry (NAICS 238160)
SIOUX FALLS, SD—2026-07-13
H & R ROOFING OF SOUTH DAKOTA, INC.
HENDERSON, NV—2026-07-13
INTEGRITY ROOFING LLC
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CAMDEN, OH—2026-07-13
ALBERTO MORALES
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
More inspections in NY
POUGHKEEPSIE, NY—2026-07-13
MARCO BOARD HOUSE, INC.
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CORTLANDT MANOR, NY—2026-07-13
RJW RENOVATIONS, LLC
HEMPSTEAD, NY—2026-07-13
NYSDOCCS NASSAU AREA OFFICE
NIAGARA FALLS, NY—2026-07-10
NTVI FEDERAL INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341126936.