TULSA, OK —
OSHA Inspection: WOOD SYSTEMS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of WOOD SYSTEMS, INC. in 4615 S. 49TH WEST AVE., TULSA, OK 74107 (NAICS 321918). OSHA activity number 341130045.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WOOD SYSTEMS, INC.
- Site address
- 4615 S. 49TH WEST AVE.
- City
- TULSA
- State
- OK
- ZIP
- 74107
- Mailing
- 4615 S. 49TH WEST AVE., TULSA, OK 74107
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321918
- Employees
- 60
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.106 E06 II
- Issued
- Mar 2, 2016
- Abate by
- Mar 8, 2016
- Penalty
- Initial $1,785 · Current $1,050 Reduced
General-duty citation text
29 CFR 1910.106(e)(6)(ii): Class I flammable liquid(s) were dispensed into containers, vehicles, and equipment without electrically interconnecting the nozzle and the container, vehicles, or equipment: On or about December 15, 2015, and at times prior thereto, in the paint area lacquer thinner having flash point of 2 degrees F was dispensed into a smaller container without being effectively grounded and bonded to electrically interconnect the containers, exposing employees to a fire hazard.
Recent events (2)
- — I (O) $1050
- — Z (S) $1785
1910.107 C06
- Issued
- Mar 2, 2016
- Abate by
- Mar 24, 2016
- Penalty
- Initial $1,785 · Current $1,050 Reduced
General-duty citation text
29 CFR 1910.107(c)(6): Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined were not explosion-proof type approved for Class I, group D locations and did not otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations: On or about December 15, 2015, and at times prior thereto, in the spray booth area electrical outlets and switches were observed within 5 feet of the opening of an open face spray booth were not the type approved for Class I, Division 1, hazardous locations. Employees were exposed to fire hazards.
Recent events (2)
- — I (O) $1050
- — Z (S) $1785
1910.147 C04 I
- Issued
- Mar 2, 2016
- Abate by
- Mar 24, 2016
- Penalty
- Initial $2,975 · Current $1,700 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about December 15, 2015, and at times prior thereto, at the establishment the employer did not effectively develop and document proper step-by-step lock-out/tag-out procedures for the control of potentially hazardous energy of specific equipment when employees were engaged in maintenance operation. Employees were exposed to unexpected release of energy hazards.
Recent events (2)
- — I (O) $1700
- — Z (S) $2975
1910.147 C06 I
- Issued
- Mar 2, 2016
- Abate by
- Mar 24, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: On or about December 15, 2015, and at times prior thereto, at the establishment the employer had employees performing maintenance operations that require lock-out/tag-out equipment. The employer did not conduct periodic inspection of the procedures at least annually. Employees were exposed to unexpected release of energy hazards.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.22 A01
- Issued
- Mar 2, 2016
- Abate by
- Mar 8, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition: On or about December 15, 2015, and at times prior thereto, in the KOMO router area wood dust was found accumulated on floors and ledges of building.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Wood Systems, INC.