Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MCENTEE CONSTRUCTION COMPANY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MCENTEE CONSTRUCTION COMPANY in 264 FOREST ROAD, FORT LEE, NJ 07024 (NAICS 238140). OSHA activity number 341130102.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mcentee Construction Company — free Get an email when a new federal OSHA severe-injury report for Mcentee Construction Company is published. One employer, no account, unsubscribe in one click.
Site address
264 FOREST ROAD
City
FORT LEE
State
NJ
ZIP
07024
Mailing
20 EDISON DRIVE, WAYNE, NJ 07470
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
4
Ownership type
A

5 citations on file for this inspection.

1926.451 C02 II

Serious Gravity 5 1 instance 4 exposed
Issued
Feb 17, 2016
Penalty
Initial $2,200 · Current $750 Reduced
29 CFR 1926.451(c)(2)(ii): Unstable objects were used to support scaffolds or platform units:      a) Building Exterior:  A scaffold seven frames in height was supported on a stacked pieces of cut wood, on or about 12/17/2015.
Recent events (3)
  • — F (S) $750
  • — C (S) $2200
  • — Z (S) $2200

1926.452 C02

Serious Gravity 5 1 instance 4 exposed
Issued
Feb 17, 2016
Penalty
Initial $1,760 · Current $500 Reduced
29 CFR 1926.452(c)(2): Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally:      a) Building Exterior:  Cross braces were missing on sections of a scaffold seven frames in height, on or about 12/17/2015.
Recent events (3)
  • — F (S) $500
  • — C (S) $1760
  • — Z (S) $1760

1926.501 B13

Serious Gravity 10 1 instance 4 exposed
Issued
Feb 17, 2016
Penalty
Initial $3,080 · Current $1,250 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):       (a) Building Roof: Two  employees were exposed to a fall hazard of approximately 30 feet while on the roof without the use of use of guardrail systems, safety net systems or personal fall arrest systems, on or about 12/17/2015.
Recent events (3)
  • — F (S) $1250
  • — C (S) $3080
  • — Z (S) $3080

1926.451 C02

Deleted Repeat Gravity 10 1 instance 5 exposed
Issued
Feb 17, 2016
Penalty
Initial $6,160 · Current $0 Reduced
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames,  or uprights did not bear on base plates, mud sills or other adequate firm foundation:   a) Building Exterior:  Fabricated Scaffolds seven frames in height were not supported on base plates, on or about 12/17/2015.   The McEntee Construction Company was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.451(c)(2), which was contained in OSHA inspection number 314675513, citation number 1, item number 1 and was affirmed as a final order on 1/14/2011, with respect to a workplace located at 90 West Commercial Ave, Moonachie, NJ 07470.
Recent events (3)
  • — F (R) $0
  • — C (R) $6160
  • — Z (R) $6160

1926.451 G01

Repeat Gravity 10 1 instance 5 exposed
Issued
Feb 17, 2016
Penalty
Initial $6,160 · Current $2,500 Reduced
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section:      a) Building Exterior:  Employees exposed to a fall hazard of approximately 42 feet while working from a fabricated scaffolds seven frames in height that was not equipped with a guardrail system, on or about 12/17/2015.      The McEntee Construction Company was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.451(g)(1), which was contained in OSHA inspection number 314675513, citation number 1, item number 4 and was affirmed as a final order on 1/14/2011, with respect to a workplace located at 90 West Commercial Ave, Moonachie, NJ 07470.
Recent events (3)
  • — F (R) $2500
  • — C (R) $6160
  • — Z (R) $6160

View Mcentee Construction Company's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341130102.