LATROBE, PA —
OSHA Inspection: BRIDGE DECK SOLUTIONS LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of BRIDGE DECK SOLUTIONS LLC in 298 CHERRY HILL DRIVE, LATROBE, PA 15650 (NAICS 332999). OSHA activity number 341137883.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BRIDGE DECK SOLUTIONS LLC
- Site address
- 298 CHERRY HILL DRIVE
- City
- LATROBE
- State
- PA
- ZIP
- 15650
- Mailing
- 298 CHERRY HILL DRIVE, LATROBE, PA 15650
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- Employees
- 13
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.147 C07
- Issued
- Dec 28, 2015
- Abate by
- Jan 25, 2016
- Penalty
- Initial $2,550 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(7): The employer did not provide training to ensure that the purpose and functions of he energy control program are understood by employees and that the knowledge and skills required for the safe application, useage, and removal of the energy controls are acquired by employees. The training shall include: (A) Each authorized employee shall receive training in the recognition of the applicable hazarrdous energy sources, the type and mangnitude of the energy available in the workplace, and the methods and means necessary for energy isoltion and control. (B) Each affected employee shall be instructed in the purpose and use of the energy control procedure. (C) All other employees shall be instructed about the procedure, and about the prohibition relating to attempts to restart or reenergize machines or equipment which are locked or tagged out: (a) Facility: On or about December 21, 2014, two (affected) employees were not trained in the company's lockout/tagout program.
Recent events (2)
- — I (O) $0
- — Z (S) $2550
1910.303 B07
- Issued
- Dec 28, 2015
- Abate by
- Jan 25, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(7): 29 CFR 1910.303(b)(7): Electrical equipment was not installed in a neat and workmanlike manner: Facility: On or about December 21, 2015, the Niagara 6 foot shear had its on/off switch not working and the company was using the machines electrical disconnect as its on/off switch.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G01 IV
- Issued
- Dec 28, 2015
- Abate by
- Jan 25, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv): Flexible cords and/ or cables were used for purposes prohibited by paragraphs (A) through (F) of 29 CFR 1910.305(g)(1)(iv)(a): (a) Facility: On or about December 21, 2015, employees were using a 480v AC electrical extension cord to provide power to the 4 inch Bradbury roller.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 H01
- Issued
- Dec 28, 2015
- Abate by
- Jan 25, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (a) Facility: On or about December 21, 2015, two employees were not trained in the company's hazard communication program.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.212 A01
- Issued
- Dec 28, 2015
- Abate by
- Jan 25, 2016
- Penalty
- Initial $4,250 · Current $4,000 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) Facility: On or about December 21, 2015, the Plexiglas shear guard to the 6 foot Niagara had a minimum opening of 1 1/16 inches and the shear point was only 3 3/4 inches from the shear guard.
Recent events (2)
- — I (S) $4000
- — Z (S) $4250
More inspections in this industry (NAICS 332999)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341137883.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.