Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MAINTENANCE AMERICA LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of MAINTENANCE AMERICA LLC in 1375 W CHURCH STREET, JACKSONVILLE, FL 32099 (NAICS 493110). OSHA activity number 341137909.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Maintenance America LLC — free Get an email when a new federal OSHA severe-injury report for Maintenance America LLC is published. One employer, no account, unsubscribe in one click.
Site address
1375 W CHURCH STREET
City
JACKSONVILLE
State
FL
ZIP
32099
Mailing
1375 W CHURCH STREET, JACKSONVILLE, FL 32099
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493110
Employees
4
Ownership type
A

2 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 24, 2016
Penalty
Initial $1,700 · Current $850 Reduced
29 CFR 1910.212(a)(1):  One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts and flying chips:    a.  On or about December 2, 2015, employees using the styrofoam densifier in the warehouse were exposed to a caught in hazard, in that there were no guards preventing the employees from falling into the densifier.
Recent events (2)
  • — I (S) $850
  • — Z (S) $1700

1910.305 B01 II

Other-than-serious 1 instance 1 exposed
Issued
Mar 24, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  a.  On or about December 2, 2015, the bailer had unused openings that were not effectively closed, exposing employees to an electrical arc flash.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341137909.