WASHINGTON, DC —
OSHA Inspection: STILLWATER CONSTRUCTION GROUP, LLC
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of STILLWATER CONSTRUCTION GROUP, LLC in 4801 N. CAPITOL ST., NE, WASHINGTON, DC 20010 (NAICS 423330). OSHA activity number 341144376.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- STILLWATER CONSTRUCTION GROUP, LLC
- Site address
- 4801 N. CAPITOL ST., NE
- City
- WASHINGTON
- State
- DC
- ZIP
- 20010
- Mailing
- P.O. BOX 463, GREAT FALLS, VA 22066
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423330
- Employees
- 10
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.502 J07 I
- Issued
- Feb 19, 2016
- Penalty
- Initial $2,100 · Current $1,470 Reduced
General-duty citation text
29 CFR 1926.502(j)(7)(i): 29 CFR 1926.502(j)(7)(i): Material and equipment shall not be stored within 6 feet (1.8m) of a roof edge unless guardrails are erected at the edge: a) Lower Roof On or about 12/11/2015, no guardrails were provided where roofing insulation panels were stacked 5 feet high and were placed within 1 of the unprotected edge of a flat roof. b) Lower Roof On or about 12/11/2015, no guardrails were provided where roofing insulation panels were stacked 5 feet high and were placed within 4 of the unprotected edge of a flat roof. No abatement certification or documentation required for this item.
Recent events (2)
- — I (O) $1470
- — Z (S) $2100
1926.502 H01 III
- Issued
- Feb 19, 2016
- Penalty
- Initial $3,500 · Current $2,450 Reduced
General-duty citation text
29 CFR 1926.502(h)(1)(iii): The safety monitor was not on the same walking/working surface and within visual sighting distance of the employee being monitored: a) Upper Roof On or about 12/11/2015, a roofer designated by the employer as the roof monitor left a 80 foot by 45 foot flat roof during active roofing operation and was not within visual sighting distance of the roofing crew. No abatement certification or documentation required for this item.
Recent events (2)
- — I (O) $2450
- — Z (S) $3500
More inspections at Stillwater Construction Group, LLC
View Stillwater Construction Group, LLC's full OSHA safety record →
More inspections in this industry (NAICS 423330)
More inspections in DC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341144376.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.