DEVENS, MA —
OSHA Inspection: COMMONWEALTH ELECTRICAL TECHNOLOGIES, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of COMMONWEALTH ELECTRICAL TECHNOLOGIES, INC. in 66 SARATOGA BLVD., DEVENS, MA 01434 (NAICS 237130). OSHA activity number 341145225.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COMMONWEALTH ELECTRICAL TECHNOLOGIES, INC.
- Site address
- 66 SARATOGA BLVD.
- City
- DEVENS
- State
- MA
- ZIP
- 01434
- Mailing
- 66 SARATOGA BLVD, DEVENS, MA 01434
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237130
- Employees
- 35
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.251 A02 III
- Issued
- Mar 21, 2016
- Abate by
- Mar 25, 2016
- Penalty
- Initial $3,850 · Current $1,925 Reduced
General-duty citation text
29 CFR 1926.251(a)(2)(iii): Employer did not ensure that rigging equipment was used that had affixed, legible identification markings, required by paragraph (a)(2)(i) of this section. 66 Saratoga Blvd. Devens, MA On or about 12/3/15 through 12/10/15 the employer used damaged/defective synthetic slings with non-legible identification labels to crane hoist equipment and materials to the roof of a warehouse building.
Recent events (2)
- — I (O) $1925
- — Z (S) $3850
1926.251 A03
- Issued
- Mar 21, 2016
- Abate by
- Mar 25, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.251(a)(1): Defective rigging equipment was not removed from service. 66 Saratoga Blvd. Devens, MA On or about 12/3/15 through 12/10/15 the employer failed to remove damaged/defective synthetic slings from service that were used to crane hoist equipment and materials to the roof of a warehouse building.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1926.602 D
- Issued
- Mar 21, 2016
- Abate by
- Apr 14, 2016
- Penalty
- Initial $3,850 · Current $1,925 Reduced
General-duty citation text
29 CFR 1926.602(d): The employer did not certify that each operator had been trained and evaluated as required by paragraph 29 CFR 1910.178(l): 66 Saratoga Blvd. Devens, MA On or about 12/3/15 through 12/10/15 the employer failed to certify and evaluate the JCB Rough-Terrain Powered Industrial Truck operator.
Recent events (2)
- — I (O) $1925
- — Z (S) $3850
1926.1430 B
- Issued
- Mar 21, 2016
- Abate by
- Mar 25, 2016
- Penalty
- Initial $3,850 · Current $1,925 Reduced
General-duty citation text
29 CFR 1926.1430(b): The employer did not train each employee assigned as a signal person who did not meet the requirements of 1926.1428(c) in the areas addressed in that paragraph: 66 Saratoga Blvd. Devens, MA On or about 12/3/15 through 12/10/15 Two employees performing signaling for roof and ground crane support operations using radio and hand signals had not been trained in accordance with 29CFR 1926.1428(c)(1-5).
Recent events (2)
- — I (S) $1925
- — Z (S) $3850
More inspections at Commonwealth Electrical Technologies, INC.
View Commonwealth Electrical Technologies, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 237130)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341145225.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.