BRUNSWICK, ME —
OSHA Inspection: SEAL IT INSULATION SYSTEMS
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of SEAL IT INSULATION SYSTEMS in 17 TURNER STREET, BRUNSWICK, ME 04011 (NAICS 238310). OSHA activity number 341152841.
Where did this inspection happen?
- Establishment
- SEAL IT INSULATION SYSTEMS
- Site address
- 17 TURNER STREET
- City
- BRUNSWICK
- State
- ME
- ZIP
- 04011
- Mailing
- 17 TURNER STREET, BRUNSWICK, ME 04011
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238310
- Employees
- 13
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.134 E01
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: Seal It Insulation Systems - On or about December 22, 2015, the employer did not provide a medical evaluation for the employees who, on a mandatory basis, used the full face, air supplied respirator and half face fitted respirator when applying isocyanates (such as but not limited to 1,6-Hexamethylene Diisocyanate Homopolymer, Methylene Bisphenyl Isocyanate, and Hexamethylene Diisocyanate) in the workplace.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1910.134 F02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(f)(2): Employee(s) using a tight-fitting facepiece respirator were not annually fit tested: Seal It Insulation Systems - On or about December 22, 2015, employees were using mandatory half face fitted respirators for use when spraying with isocyanates and were not annually fit tested.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 H03 III
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1910.1200(h)(3)(iii): Employee training did not include the measures employees can take to protect themselves from chemical hazards, including specific procedures the employer had implemented to protect employees from exposure to hazardous chemicals, such as appropriate work practices, emergency procedures and personal protective equipment to be used: Seal It Insulation Systems - On or about February 10, 2016, employees were not provided with effective training and information regarding the isocyantes (such as but not limited to 1,6-Hexamethylene Diisocyanate Homopolymer, Methylene Bisphenyl Isocyanate, and Hexamethylene Diisocyanate) used in the workplace including measures to take to protect themselves from exposure to these hazards (for example, hand protection and specific air respirator cartridges).
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1910.1200 H03 IV
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(h)(3)(iv): The details of the hazard communication program developed by the employer, did not include an explanation of the safety data sheet, including the order of information and how employee could obtain and use the appropriate hazard information: Seal It Insulation Systems - On or about February 10, 2016, employees were not provided with effective training and information regarding the isocyantes (such as but not limited to 1,6-Hexamethylene Diisocyanate Homopolymer, Methylene Bisphenyl Isocyanate, and Hexamethylene Diisocyanate) used in the workplace including explanation of safety data sheets and the how to use the appropriate hazard information.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.157 E02
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly: Seal It Insulation Systems, Office and Supply Areas - The portable fire extinguishers provided in the workplace were not inspected on a monthly basis.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 238310)
BANNOCKBURN, IL—2026-07-16
BUILDER SERVICES GROUP, INC. DBA CJ INSULATION
NAMPA, ID—2026-07-15
INTERIOR SYSTEMS, INC.
BRIDGEPORT, WV—2026-07-14
EASLEY & RIVERS, INC.
ELLETTSVILLE, IN—2026-07-13
ENVIRO HEAT, LLC
ELLETTSVILLE, IN—2026-07-13
RWS INSULATION SERVICES, LLC
More inspections in ME
AUGUSTA, ME—2026-07-14
JJ GONZALEZ ROOFING AND GUTTERS
DOVER FOXCROFT, ME—2026-07-14
REDI-ROCK OF CENTRAL MAINE
PORTLAND, ME—2026-07-06
NEW ENGLAND REHABILITATION HOSPITAL OF PORTLAND
DOVER FOXCROFT, ME—2026-07-06
SHAW'S SUPERMARKETS
GORHAM, ME—2026-07-02
TOWN OF GORHAM
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341152841.