BRANDON, MS —
OSHA Inspection: MALONE ROOFING SERVICES, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MALONE ROOFING SERVICES, LLC in 1400 W.GOVERNMENT STREET, BRANDON, MS 39042 (NAICS 238160). OSHA activity number 341154060.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MALONE ROOFING SERVICES, LLC
- Site address
- 1400 W.GOVERNMENT STREET
- City
- BRANDON
- State
- MS
- ZIP
- 39042
- Mailing
- 439 DORY STREET, JACKSON, MS 39201
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 10
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.501 B10
- Issued
- Mar 1, 2016
- Abate by
- Mar 3, 2016
- Penalty
- Initial $6,300 · Current $6,700
General-duty citation text
29 CFR 1926.501(b)(10): "Roofing work on Low-slope roofs." Except as otherwise provided in paragraph (b) of this section, each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width (see Appendix A to subpart M of this part), the use of a safety monitoring system alone [i.e. without the warning line system] is permitted. (a) Porch area - On or about December 31, 2015 employees were exposed to a fall hazard while working on a flat roof 28 feet above concrete with no fall protection.
Recent events (2)
- — I (S) $6700
- — Z (S) $6300
1926.501 B11
- Issued
- Mar 1, 2016
- Abate by
- Mar 3, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.501(b)(11): "Steep roofs." Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems. (a) Main Roof of Priority One Bank - On or about December 31, 2015 employees were exposed to a fall hazard while working on a steep roof 35 feet the ground with no fall protection. The pitch of the roof was 7/12.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.502 H01 III
- Issued
- Mar 1, 2016
- Abate by
- Mar 3, 2016
- Penalty
- Initial $6,300 · Current $0 Reduced
General-duty citation text
29 CFR 1926.502(h)(1)(iii): The safety monitor shall be on the same walking/working surface and within visual sighting distance of the employee being monitored (a) Porch area - On or about December 31, 2015 employees were exposed to a fall hazard while working on a flat roof due to the safety monitor not being on the same level and not actively observing all employees involved in work on the roof.
Recent events (2)
- — I (S) $0
- — Z (S) $6300
1910.1200 E01
- Issued
- Mar 1, 2016
- Abate by
- Mar 11, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1): Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, material safety data sheets, and employee information and training will be met, and which also includes the following: (a) Priority One Bank (construction site) - On or about December 31, 2015 the employer did not maintain a Hazardous Communication Program. Employees were exposed to potential serious injury while using a Flammable Liquid known as Firestone Ultra-Ply Bonding Adhesive without the availability of a Safety Data Sheet (SDS) in the work area.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1926.1412 K
- Issued
- Mar 1, 2016
- Abate by
- Mar 11, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1412(k): All documents produced under this section must be available, during the applicable document retention period, to all persons who conduct inspections under this section. [75 FR 48146, August 9, 2010] (a) Priority One Bank - On or about December 31, 2015 there was a crane truck in operation with no crane current records available on-site for inspection. The records inside the vehicle were from 2011. Crane records such as: load charts, operator manual, operating speeds, special hazard warnings, instructions were not current or available for inspection.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1926.1413 E
- Issued
- Mar 1, 2016
- Abate by
- Mar 11, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1413(e): All documents produced under this section must be available, during the applicable document retention period, to all persons who conduct inspections under this section. [75 FR 48148, August 9, 2010] (a) Priority One Bank - On or about December 31, 2015 there was a crane truck in operation with no crane current records available on-site for inspection. The records inside the vehicle were from 2011. Crane record such as: wire rope inspection records were not current or available for inspection.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1926.1417 C01
- Issued
- Mar 1, 2016
- Abate by
- Mar 11, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1417(c)(1): The procedures applicable to the operation of the equipment, including rated capacities (load charts), recommended operating speeds, special hazard warnings, instructions, and operator's manual, must be readily available in the cab at all times for use by the operator. (a) Priority One Bank - On or about December 31, 2015 there was a crane truck in operation with no crane current records available on-site for inspection. The records inside the vehicle were from 2011. Crane records such as: safety device or operational aid, critical part control system, power plant, braking system, load sustaining structure, structural components etc. were not current or available for inspection.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Malone Roofing Services, LLC
View Malone Roofing Services, LLC's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in MS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341154060.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.