Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MSL CONSTRUCTION, LLC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MSL CONSTRUCTION, LLC. in 737 61ST ST., BROOKLYN, NY 11220 (NAICS 238910). OSHA activity number 341156024.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch MSL Construction, LLC. — free Get an email when a new federal OSHA severe-injury report for MSL Construction, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
737 61ST ST.
City
BROOKLYN
State
NY
ZIP
11220
Mailing
92-29 QUEENS BLVD. SUITE C2, REGO PARK, NY 11374
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238910
Employees
15
Ownership type
A

3 citations on file for this inspection.

1926.403 H

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 11, 2016
Abate by
Feb 22, 2016
Penalty
Initial $1,600 · Current $1,200 Reduced
29 CFR 1926.403(h): Each service, feeder, and branch circuit was not legibly marked at its disconnecting means or overcurrent device to indicate its purpose, nor located and arranged so that the purpose was evident:    a) Interior of the 61st Street wall - On or about January 5, 2016 and at times prior thereto, the employer had a temporary panel breaker box installed to provide 110 V power for multiple power tools and equipment.  The breaker box was not labeled indicating the purpose of the different switches.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $1600

1926.403 I02 I

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 11, 2016
Abate by
Feb 22, 2016
Penalty
Initial $2,000 · Current $1,500 Reduced
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures.      a) Interior of the 61st Street wall - On or about January 5, 2016 and at times prior thereto, the employer had a temporary panel breaker box installed to provide 110 V power for multiple power tools and equipment.  The breaker box had multiple missing knock out plates exposing live parts underneath.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2000

1926.1052 C01

Serious Gravity 5 1 instance 4 exposed
Issued
Feb 11, 2016
Abate by
Feb 22, 2016
Penalty
Initial $1,600 · Current $1,200 Reduced
29 CFR 1926.1052(c)(1): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail and one stair rail system along each unprotected side or edge:      a) Main door, site entrance - On or about January 5, 2016 and at times prior thereto, an employee and sub-contractors use a stairway with 4 risers that does not have a hand rail or stair rail system on either unprotected side.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $1600

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341156024.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.