Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SYRACUSE HEAT TREATING CORPORATION

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of SYRACUSE HEAT TREATING CORPORATION in 7055 INTERSTATE ISLAND ROAD, SYRACUSE, NY 13209 (NAICS 332811). OSHA activity number 341157253.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Syracuse Heat Treating Corporation — free Get an email when a new federal OSHA severe-injury report for Syracuse Heat Treating Corporation is published. One employer, no account, unsubscribe in one click.
Site address
7055 INTERSTATE ISLAND ROAD
City
SYRACUSE
State
NY
ZIP
13209
Mailing
7055 INTERSTATE ISLAND ROAD, SYRACUSE, NY 13209
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332811
Employees
24
Ownership type
A

3 citations on file for this inspection.

1910.23 A08

Serious Gravity 1 1 instance 2 exposed
Issued
Feb 8, 2016
Abate by
Mar 12, 2016
Penalty
Initial $1,200 · Current $900 Reduced
29 CFR 1910.23(a)(8): Every floor hole into which persons can accidentally walk were not guarded:     a) In the fluid bed area, on or about 1/5/16: The top opening of a treatment tank containing oil was not guarded to protect employees from falling into the tank.      Abatement certification must be submitted for this item.
Recent events (2)
  • — I (S) $900
  • — Z (S) $1200

1910.147 C06 I

Serious Gravity 5 1 instance 3 exposed
Issued
Feb 8, 2016
Abate by
Mar 12, 2016
Penalty
Initial $1,600 · Current $1,200 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:    a) At the facility, on or about 2/2/16: The employer did not conduct a periodic inspection of energy control procedures for equipment including but not limited to ovens/furnaces.     Abatement certification must be submitted for this item.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $1600

1910.146 D14

Other-than-serious 1 instance 3 exposed
Issued
Feb 8, 2016
Abate by
Mar 12, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.146(d)(14): Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), the employer did not review the permit-required confined space program, using the canceled permits retained under 29 CFR 1910.146(e)(6) within one year. NOTE: Employers may perform a single annual review covering all entries performed during 12-month period. If no entry is performed during a 12-month period, no review is necessary.    a) At the facility, on or about 2/2/16: The employer did not review the permit required confined space program and canceled permits annually.    Abatement certification must be submitted for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Syracuse Heat Treating Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341157253.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.