Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: UNITED STATES ARMY NATIONAL GUARD

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of UNITED STATES ARMY NATIONAL GUARD in B50 1 WILLIAMS DRIVE, CAMP DOUGLAS, WI 54618 (NAICS 928110). OSHA activity number 341159663.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch United States Army National Guard — free Get an email when a new federal OSHA severe-injury report for United States Army National Guard is published. One employer, no account, unsubscribe in one click.
Site address
B50 1 WILLIAMS DRIVE
City
CAMP DOUGLAS
State
WI
ZIP
54618
Mailing
2400 WRIGHT STREET, MADISON, WI 53704
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
928110
Employees
57
Ownership type
D

3 citations on file for this inspection.

1910.1027 K01

Other-than-serious 1 instance 3 exposed
Issued
Apr 14, 2016
Abate by
Jul 27, 2016
Penalty
Initial $0 · Current $0

Hazardous substances C141

29 CFR 1910.1027(k)(1): All surfaces shall be maintained as free as practicable of accumulations of cadmium.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.1027 K06

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Apr 14, 2016
Abate by
May 12, 2016
Penalty
Initial $0 · Current $0

Hazardous substances C141

29 CFR 1910.1027(k)(6): Compressed air was used to remove cadmium from a surface without being in conjunction with a ventilation system to capture the dust cloud:  Electronic technicians used compressed air to clean work benches that were contaminated with cadmium.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1027 D01 I

Deleted Other-than-serious 1 instance 3 exposed
Issued
Apr 14, 2016
Penalty
Initial $0 · Current $0

Hazardous substances 0490C141

29 CFR 1910.1027(d)(1)(i): The employer did not determine whether any employee was exposed to cadmium at or above the action level:  On or about January 06, 2016 electronic technicians cadmium exposure was not evaluated.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341159663.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.