CAMP DOUGLAS, WI —
OSHA Inspection: UNITED STATES ARMY NATIONAL GUARD
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of UNITED STATES ARMY NATIONAL GUARD in B50 1 WILLIAMS DRIVE, CAMP DOUGLAS, WI 54618 (NAICS 928110). OSHA activity number 341159663.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- UNITED STATES ARMY NATIONAL GUARD
- Site address
- B50 1 WILLIAMS DRIVE
- City
- CAMP DOUGLAS
- State
- WI
- ZIP
- 54618
- Mailing
- 2400 WRIGHT STREET, MADISON, WI 53704
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 928110
- Employees
- 57
- Ownership type
- D
Citations
3 citations on file for this inspection.
1910.1027 K01
- Issued
- Apr 14, 2016
- Abate by
- Jul 27, 2016
- Penalty
- Initial $0 · Current $0
C141
General-duty citation text
29 CFR 1910.1027(k)(1): All surfaces shall be maintained as free as practicable of accumulations of cadmium.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.1027 K06
- Issued
- Apr 14, 2016
- Abate by
- May 12, 2016
- Penalty
- Initial $0 · Current $0
C141
General-duty citation text
29 CFR 1910.1027(k)(6): Compressed air was used to remove cadmium from a surface without being in conjunction with a ventilation system to capture the dust cloud: Electronic technicians used compressed air to clean work benches that were contaminated with cadmium.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1027 D01 I
- Issued
- Apr 14, 2016
- Penalty
- Initial $0 · Current $0
0490C141
General-duty citation text
29 CFR 1910.1027(d)(1)(i): The employer did not determine whether any employee was exposed to cadmium at or above the action level: On or about January 06, 2016 electronic technicians cadmium exposure was not evaluated.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 928110)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341159663.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.