Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: R & R GENERAL CONTRACTORS, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of R & R GENERAL CONTRACTORS, INC. in 4666 E FARIES PKWY, DECATUR, IL 62526 (NAICS 238290). OSHA activity number 341160570.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch R & R General Contractors, INC. — free Get an email when a new federal OSHA severe-injury report for R & R General Contractors, INC. is published. One employer, no account, unsubscribe in one click.
Site address
4666 E FARIES PKWY
City
DECATUR
State
IL
ZIP
62526
Mailing
505 N. STATE HWY 121, MOUNT ZION, IL 62549
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238290
Employees
175
Ownership type
A

4 citations on file for this inspection.

1910.146 D03 IV

Serious Gravity 10 1 instance 1 exposed
Issued
Feb 10, 2016
Abate by
Feb 17, 2016
Penalty
Initial $7,000 · Current $3,500 Reduced
29 CFR 1910.146(d)(3)(iv): Under the permit space program, the employer did not develop and implement the means, procedures, and practices necessary for safe permit entry operations, including, but not limited to, purging, interting, flushing or ventilation the permit spaces as necessary to eleminate or control atmospheric hazards.    On or about December 31, 2015, employees making a permit required confined space entry into the #5 Sorbitol Reactor at the ADM Corn Plant were exposed to an oxygen-deficient atmosphere containing nitrogen and the employer did not implement the means and practices necessary to ventilate the permit space as necessary to eliminate or control the atmospheric hazard.
Recent events (2)
  • — I (S) $3500
  • — Z (S) $7000

1910.146 D03 VI

Serious Gravity 10 1 instance 1 exposed
Issued
Feb 10, 2016
Abate by
Feb 17, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.146(d)(3)(vi): Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), the employer did not develop and implement the means, procedures, and practices to verify that conditions in a permit space were acceptable for entry throughout the duration of an authorized entry:  On or about December 31, 2015, employees making a permit required confined space entry into the #5 Sorbitol Reactor at the ADM Corn Plant were exposed to an oxygen-deficient atmosphere containing nitrogen and the employer did not implement the means and practices necessary to ensure the permit space conditions in the space were acceptable for entry throughout the duration of the authorized entry.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.146 D05 I

Serious Gravity 10 1 instance 1 exposed
Issued
Feb 10, 2016
Abate by
Feb 17, 2016
Penalty
Initial $7,000 · Current $3,500 Reduced
29 CFR 1910.146(d)(5)(i): The employer did not test conditions in the permit space to determine if acceptable entry conditions existed before entry was authorized:    On or about December 31, 2015, employees making a permit required confined space entry into the #5 Sorbitol Reactor at the ADM Corn Plant were exposed to an oxygen-deficient atmosphere containing nitrogen and the employer did not adequately test conditions in the permit space including, but not limited to, testing the air in the space at working height, before  entry to determine if acceptable entry conditions existed before entry was authorized.
Recent events (2)
  • — I (S) $3500
  • — Z (S) $7000

1910.146 D05 II

Serious Gravity 10 1 instance 1 exposed
Issued
Feb 10, 2016
Abate by
Feb 17, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.146(d)(5)(ii): Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), the employer did not evaluate permit space conditions when entry operations were conducted by testing or monitoring the permit space as necessary to determine if acceptable entry conditions were being maintained during the course of entry operations:  On or about December 31, 2015, employees making a permit required confined space entry into the #5 Sorbitol Reactor at the ADM Corn Plant were exposed to an oxygen-deficient atmosphere containing nitrogen and the employer did not adequately test conditions in the permit space including, but not limited to, testing the air in the space at working height, during entry operations to ensure that acceptable entry conditions existed during the course of all entry into the space.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View R & R General Contractors, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341160570.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.