AMORY, MS —
OSHA Inspection: PARHEN FOUNDRY, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of PARHEN FOUNDRY, INC. in 100 WATERWAY DRIVE, AMORY, MS 38821 (NAICS 331511). OSHA activity number 341160802.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PARHEN FOUNDRY, INC.
- Site address
- 100 WATERWAY DRIVE
- City
- AMORY
- State
- MS
- ZIP
- 38821
- Mailing
- 100 WATERWAY DRIVE, AMORY, MS 38821
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331511
- Employees
- 3
- Ownership type
- A
Citations
11 citations on file for this inspection.
1910.22 A01
- Issued
- Mar 1, 2016
- Abate by
- May 2, 2016
- Penalty
- Initial $2,000 · Current $1,086 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): Storage of equipment and materials were in a manner which created a hazard. (a) Facility - On or about January 04, 2016 employees exposed to tripping hazards while walking in the aisles near forming molds and patterns.
Recent events (2)
- — I (S) $1086
- — Z (S) $2000
1910.151 C
- Issued
- Mar 1, 2016
- Abate by
- Mar 30, 2016
- Penalty
- Initial $2,000 · Current $1,086 Reduced
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: (a) Facility - On or about January 04, 2016 employer did not furnish an operable eye wash station.
Recent events (2)
- — I (S) $1086
- — Z (S) $2000
1910.178 P01
- Issued
- Mar 1, 2016
- Abate by
- Mar 30, 2016
- Penalty
- Initial $2,000 · Current $1,086 Reduced
General-duty citation text
29 CFR 1910.178(p)(1): 29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe, the truck shall be taken out of service until it has been restored to safe operating condition. (a) Facility - On or about January 04, 2016 employee operated a Clark LP powered industrial truck without brakes.
Recent events (2)
- — I (S) $1086
- — Z (S) $2000
1910.179 J03
- Issued
- Mar 1, 2016
- Abate by
- May 2, 2016
- Penalty
- Initial $2,000 · Current $1,086 Reduced
General-duty citation text
29 CFR 1910.179(j)(3): Complete periodic inspections of the crane were not performed at intervals as generally defined in paragraph (j)(1)(ii)(b) of this section: (a) Facility - On or about January 04, 2016 a 7 1/2 ton overhead crane has not been periodically inspected in the last 12 months.
Recent events (2)
- — I (S) $1086
- — Z (S) $2000
1910.212 A01
- Issued
- Mar 1, 2016
- Penalty
- Initial $2,000 · Current $1,086 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. (a) Facility - On or about January 04. 2016 the employer did not guard the revolving drum of a tumbler.
Recent events (2)
- — I (S) $1086
- — Z (S) $2000
1910.1200 E01
- Issued
- Mar 1, 2016
- Abate by
- May 2, 2016
- Penalty
- Initial $1,600 · Current $870 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement and maintain at the workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g) and (h) of this section for labels and other forms of warning, material safety data sheets, and employee information and training will be met: (a) Facility - On or about January 04, 2016 the employer had not developed a written hazard communication program for employees who were exposed to chemicals including, but not limited to, Chem-rez Duraset (Furfuryl alcohol), Furaset Resin, and Prosolv.
Recent events (2)
- — I (S) $870
- — Z (S) $1600
1910.132 H01
- Issued
- Mar 1, 2016
- Abate by
- Mar 30, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(h)(1): Personal protective equipment (PPE), was not provided by the employer at no cost to employees. (a) Facility - On or about January 04, 2016 employees purchase leather gloves and safety glasses which are required PPE.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.178 L06
- Issued
- Mar 1, 2016
- Abate by
- Mar 30, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(6): Certification. The employer shall certify that each operator has been trained and evaluated as required by this paragraph (l). The certification shall include the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation. (a) Facility - On or about January 04, 2016 forklift operators have not been certified by the employer.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 B01 I
- Issued
- Mar 1, 2016
- Abate by
- Mar 30, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasion, and openings through which conductors entered were not effectively closed: (a) Tumbler - On or about January 04, 2016 flexible cord was not protected from abrasion and effectively closed where it entered an electrical box.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 B01 II
- Issued
- Mar 1, 2016
- Abate by
- Mar 30, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings shall be effectively closed. (a) Tumbler - On or about January 04, 2016 an opening in a 110 volt electrical box was not closed.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 B02 I
- Issued
- Mar 1, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(2)(i): All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear. (a) Paint Mixer - On or about January 04, 2016 electrical junction box cover was missing.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Parhen Foundry, INC.
View Parhen Foundry, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 331511)
More inspections in MS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341160802.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.