CLEVES, OH —
OSHA Inspection: BLAU MECHANICAL, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of BLAU MECHANICAL, INC. in 8575 BRIDGETOWN RD., CLEVES, OH 45002 (NAICS 238220). OSHA activity number 341163426.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BLAU MECHANICAL, INC.
- Site address
- 8575 BRIDGETOWN RD.
- City
- CLEVES
- State
- OH
- ZIP
- 45002
- Mailing
- 1532 RUSSELL STREET, COVINGTON, KY 41011
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238220
- Employees
- 25
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.147 C07 I A
- Issued
- Mar 11, 2016
- Abate by
- Mar 30, 2016
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control. Employees performing servicing, maintenance, and troubleshooting equipment such as but not limited to a Kewanee boiler system were not trained on the specific procedures necessary for energy isolation and control of natural gas and electrical disconnect. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
- — I (S) $0
- — Z (S) $2800
1910.147 D
- Issued
- Mar 11, 2016
- Abate by
- Mar 30, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d): Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence: Employees performing servicing and maintenance on the Kewanee boiler system were not required to: (1) Know the type and magnitude of energy, the hazards of the energy to be controlled, and the method or means to control the energy, (2) turn off and shut down equipment such as but not limited to Kewanee boiler system (3) physically locate and operate the energy isolating devices in such a manner as to isolate the machine or equipment from the energy source, (4) affix lockout or tagout devices to each energy isolating device, (5) prior to starting work on equipment such as but not limited to Kewanee boiler system that have been locked out or tagged out, verify that isolation and deenergization of the boiler system have been accomplished. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 F01
- Issued
- Mar 11, 2016
- Abate by
- Mar 30, 2016
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
1910.147(f)(1) Testing or positioning of machines, equipment or components thereof. In situations in which lockout or tagout devices must be temporarily removed from the energy isolating device and the machine or equipment energized to test or position the machine, equipment or component thereof, the following sequence of actions shall be followed: Employee performing testing of equipment such as but not limited to Kewanee boiler system did not perform the following: (1) Clear the machine or equipment of tools and materials (2) remove employees from the machine or equipment area in accordance with paragraph (e)(2 (3) remove the lockout or tagout devices from the machine or equipment (4) energize and proceed with testing or positioning; and (5) deenergized all systems and reapply energy control measures in accordance with paragraph (d) of this section to continue the servicing and/or maintenance. On or about January 6, 2016, an employee was performing testing on a Kewanee boiler system and did not follow any sequences prior to testing the equipment. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
- — I (S) $0
- — Z (S) $2800
1910.333 A
- Issued
- Mar 11, 2016
- Abate by
- Mar 30, 2016
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1910.333(a): "General." Safety-related work practices shall be employed to prevent electric shock or other injuries resulting from either direct or indirect electrical contacts, when work is performed near or on equipment or circuits which are or may be energized. The specific safety-related work practices shall be consistent with the nature and extent of the associated electrical hazards. On or about January 6, 2016, an employee was performing work on a Kewanee boiler system while working on or near the 110 volts of energized equipment without safety-related work practices that was specific to the task to prevent electrical shock or injuries In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
- — I (O) $2800
- — Z (S) $2800
1910.333 C02
- Issued
- Mar 11, 2016
- Abate by
- Mar 30, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.333(c)(2): "Work on energized equipment." Only qualified persons may work on electric circuit parts or equipment that have not been deenergized under the procedures of paragraph (b) of this section. Such persons shall be capable of working safely on energized circuits and shall be familiar with the proper use of special precautionary techniques, personal protective equipment, insulating and shielding materials, and insulated tools. On or about January 6, 2016, an employee was working on a Kewanee boiler system electrical circuit that had not been deenergized and that the employee was not familiar on the procedures to be considered a qualified person to work safely on energized circuits. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.335 A01 I
- Issued
- Mar 11, 2016
- Abate by
- Mar 30, 2016
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1910.335(a)(1)(i): Employees working in areas where there are potential electrical hazards shall be provided with, and shall use, electrical protective equipment that is appropriate for the specific parts of the body to be protected and for the work to be performed. Note: Personal protective equipment requirements are contained in subpart I of this part. Employees performing electrical work such as but not limited to a Kewanee boiler system had not been provided the necessary electrical personal protective system equipment such as rated electrical clothing, electrical rated gloves, electrical rated face shield, to protect the employee form electrical shock or burns due to contact with exposed energized parts. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
- — I (O) $2800
- — Z (S) $2800
More inspections at Blau Mechanical, INC.
View Blau Mechanical, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238220)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341163426.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.