OSHA Inspection: RILEY ELECTRIC, INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of RILEY ELECTRIC, INC. in 838 N MARKET STREET, WILMINGTON, DE 19801 (NAICS 238210). OSHA activity number 341164416.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Riley Electric, INC. — free Get an email when a new federal OSHA severe-injury report for Riley Electric, INC. is published. One employer, no account, unsubscribe in one click.
Site address
838 N MARKET STREET
City
WILMINGTON
State
DE
ZIP
19801
Mailing
1235 OLD COOCHS BRIDGE ROAD, NEWARK, DE 19713
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
6
Ownership type
A

2 citations on file for this inspection.

1926.501 B01

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 16, 2016
Abate by
Apr 4, 2016
Penalty
Initial $2,800 · Current $2,100 Reduced
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.    a) Wilmington Saving Funds Society Building/9th and N. Market Street-  On or about January 7, 2016, the employer failed to protect employees from a fall  hazard of 8 1/2 feet while they installed lighting along an unprotected side/ledge approximately 18 feet wide.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $2800

1926.503 A01

Serious Gravity 1 1 instance 1 exposed
Issued
Mar 16, 2016
Abate by
Apr 4, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:  a) Wilmington Savings Funds Society/9th and N. Market Streets -On or about January 7, 2016, the employer did not provide information and training to employees in the recognition, evaluation, and control of hazards associated with working at elevations.  Employees were working from a window ledge with unprotected edges without the use of fall protection.