OSHA Inspection: INSTEEL WIRE PRODUCTS COMPANY, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of INSTEEL WIRE PRODUCTS COMPANY, INC. in 3050 MELSON AVENUE, JACKSONVILLE, FL 32254 (NAICS 331222). OSHA activity number 341166122.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Insteel Wire Products Company, INC. — free Get an email when a new federal OSHA severe-injury report for Insteel Wire Products Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3050 MELSON AVENUE
City
JACKSONVILLE
State
FL
ZIP
32254
Mailing
3050 MELSON AVENUE, JACKSONVILLE, FL 32254
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331222
Employees
100
Ownership type
A

5 citations on file for this inspection.

1910.23 C03

Serious Gravity 5 2 instances 8 exposed
Issued
Jan 21, 2016
Abate by
Feb 2, 2016
Penalty
Initial $3,825 · Current $2,295 Reduced
29 CFR 1910.23(c)(3): 29 CFR 1910.23(c)(3): Standard railing(s) and toeboard(s) were not provided on open sided floor(s), walkway(s), or runway(s), adjacent to or above dangerous equipment:    a. On January 7, 2016, on the EVG 158, the elevated platform does not have a guardrail adjacent to the weld head, exposing employees to a caught-in hazard.     b. On January 7, 2016, on the 5P, the elevated platform does not have a guardrail adjacent to the weld head, exposing employees to a caught-in hazard.
Recent events (2)
  • — I (S) $2295
  • — Z (S) $3825

1910.147 C04 I

Other-than-serious 1 instance 30 exposed
Issued
Jan 21, 2016
Abate by
Feb 24, 2016
Penalty
Initial $3,825 · Current $0 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    a. On January 7, 2016, on the plant floor, operators and helpers servicing machines such as but not limited to the GD2, 5P, EVG 158, MG330, MG24, QC7, and the Filzmoser, are not utilizing lockout tagout, exposing themselves to the hazard of getting caught-in the machines.
Recent events (2)
  • — I (O) $0
  • — Z (S) $3825

1910.212 A03 II

Serious Gravity 5 2 instances 20 exposed
Issued
Jan 21, 2016
Abate by
Feb 2, 2016
Penalty
Initial $3,825 · Current $2,295 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):    a. On January 7, 2016, in the bending department, the Steelweld shear used to cut metal does not have a guard at the point of operation, exposing employees to an amputation hazard.    b. On January 7, 2016, on the plant floor, on the EVG 158, MG24, and 5P, there are a couple openings in the machine that are not adequately guarded, exposing employees to the hazard of moving parts.
Recent events (2)
  • — I (S) $2295
  • — Z (S) $3825

1910.106 E09 III

Other-than-serious 1 instance 100 exposed
Issued
Jan 21, 2016
Abate by
Jan 28, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.106(e)(9)(iii): Combustible waste materials and residues were not stored in covered metal receptacles and disposed of daily:  a. On January 7, 2016, near the lube storage area, a large number of oily rags are being stored in a large box without a cover, exposing employees to a fire hazard.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 F06

Other-than-serious 1 instance 100 exposed
Issued
Jan 21, 2016
Abate by
Jan 29, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(6): The employer did not ensure that each container of hazardous chemicals in the workplace is labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals, and which, in conjunction with the other information immediately available to employees under the hazard communication program, will provide employees with the specific information regarding the physical and health hazards of the hazardous chemical:  a. On January 7, 2016, in the lube area, there are several unlabeled drums that contained chemicals such as used oil, kerosene, and mineral spirits without a label.