OSHA Inspection: NATIONAL DEMOLITION INC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of NATIONAL DEMOLITION INC in 1900 COLLINS AVENUE, MIAMI BEACH, FL 33139 (NAICS 238350). OSHA activity number 341170116.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch National Demolition INC — free Get an email when a new federal OSHA severe-injury report for National Demolition INC is published. One employer, no account, unsubscribe in one click.
Site address
1900 COLLINS AVENUE
City
MIAMI BEACH
State
FL
ZIP
33139
Mailing
2520 CORAL WAY STE 2380, MIAMI, FL 33145
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238350
Employees
9
Ownership type
A

3 citations on file for this inspection.

1926.501 B01

Serious Gravity 10 1 instance 3 exposed
Issued
Feb 11, 2016
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems:  On or about January, 07 2016, at the above addressed jobsite, an employee was demolishing/removing the roofing deck and the related roofing trusses from a commercial building flat roof top; and was working without the use of conventional fall protection (e.g. harness, guardrail or net), which resulted in the fall/injury to the employee.
Recent events (1)
  • — Z (S) $2800

1926.502 D09

Serious Gravity 10 1 instance 3 exposed
Issued
Feb 11, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(9): Lanyards and/or vertical lifelines did not have a minimum breaking strength of 5,000 pounds (22.2 kN):  On or about January, 07 2016, at the above addressed jobsite, an employee was demolishing/removing the roofing deck and the related roofing trusses from a 3-story commercial building flat roof top; wherein the Personal Fall Arrest System (PFAS) 50-foot lifeline was tied/knotted to a 2x4 and 2x6 roof truss, resulting in the reduction of the lifeline strength by 50 percent or more, (Ref: OSHA Appendix A to Subpart M), therefore exposing the employee to a fall hazard.
Recent events (1)
  • — Z (S) $0

1926.502 D16 III

Serious Gravity 10 1 instance 3 exposed
Issued
Feb 11, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, were not rigged such that an employee could not free fall more than 6 feet (1.8 m) nor contact any lower level:  On or about January, 07 2016, at the above addressed jobsite, two employees were demolishing/removing the roofing deck and the related roofing trusses from a 3-story commercial building flat roof top; wherein the Personal Fall Arrest Systems (PFAS) were connected to a six foot lanyard, which would have allowed the employees to have contacted the lower level (3rd floor/10'-2") in the event of a fall.