MIAMI BEACH, FL —
OSHA Inspection: NATIONAL DEMOLITION INC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of NATIONAL DEMOLITION INC in 1900 COLLINS AVENUE, MIAMI BEACH, FL 33139 (NAICS 238350). OSHA activity number 341170116.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NATIONAL DEMOLITION INC
- Site address
- 1900 COLLINS AVENUE
- City
- MIAMI BEACH
- State
- FL
- ZIP
- 33139
- Mailing
- 2520 CORAL WAY STE 2380, MIAMI, FL 33145
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238350
- Employees
- 9
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.501 B01
- Issued
- Feb 11, 2016
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: On or about January, 07 2016, at the above addressed jobsite, an employee was demolishing/removing the roofing deck and the related roofing trusses from a commercial building flat roof top; and was working without the use of conventional fall protection (e.g. harness, guardrail or net), which resulted in the fall/injury to the employee.
Recent events (1)
- — Z (S) $2800
1926.502 D09
- Issued
- Feb 11, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(d)(9): Lanyards and/or vertical lifelines did not have a minimum breaking strength of 5,000 pounds (22.2 kN): On or about January, 07 2016, at the above addressed jobsite, an employee was demolishing/removing the roofing deck and the related roofing trusses from a 3-story commercial building flat roof top; wherein the Personal Fall Arrest System (PFAS) 50-foot lifeline was tied/knotted to a 2x4 and 2x6 roof truss, resulting in the reduction of the lifeline strength by 50 percent or more, (Ref: OSHA Appendix A to Subpart M), therefore exposing the employee to a fall hazard.
Recent events (1)
- — Z (S) $0
1926.502 D16 III
- Issued
- Feb 11, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, were not rigged such that an employee could not free fall more than 6 feet (1.8 m) nor contact any lower level: On or about January, 07 2016, at the above addressed jobsite, two employees were demolishing/removing the roofing deck and the related roofing trusses from a 3-story commercial building flat roof top; wherein the Personal Fall Arrest Systems (PFAS) were connected to a six foot lanyard, which would have allowed the employees to have contacted the lower level (3rd floor/10'-2") in the event of a fall.