OSHA Inspection: JW INTERIOR AND EXTERIOR WALL SYSTEMS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JW INTERIOR AND EXTERIOR WALL SYSTEMS in FAIRFIELD INN 6593 WEIGHLOCK DRIVE, SYRACUSE, NY 13201 (NAICS 238130). OSHA activity number 341171452.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch JW Interior and Exterior Wall Systems — free Get an email when a new federal OSHA severe-injury report for JW Interior and Exterior Wall Systems is published. One employer, no account, unsubscribe in one click.
Site address
FAIRFIELD INN 6593 WEIGHLOCK DRIVE
City
SYRACUSE
State
NY
ZIP
13201
Mailing
6750 PICKARD DRIVE, SYRACUSE, NY 13211
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
16
Ownership type
A

7 citations on file for this inspection.

1926.501 B01

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Feb 24, 2016
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems:  a)  At the jobsite, on the 4th floor deck, on or about 1/5/16:  Employees were working in close proximity to the edge of a working surface, approximately 30 feet from ground without fall protection.  b)  At the jobsite, on the 4th floor deck, on or about 1/5/16:  Employees were working in close proximity to the edge of a working surface and an unprotected elevator shaft approximately 30 feet from the lower level, without fall protection.
Recent events (3)
  • — J (S) $0
  • — C (S) $2800
  • — Z (S) $2800

1926.501 B04 I

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Feb 24, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights) more than 6 feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around the openings:  a)  At the jobsite, on the 4th floor deck, on or about 1/5/16:  Employees were directly over a hole where the cover had been unsecured and the marking had worn off.    b)  At the jobsite, on the 4th floor deck, on or about 1/5/16:  Employees were working in close proximity to an unprotected hole that was adjacent to an unprotected elevator shaft.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.451 G04 II

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Feb 24, 2016
Abate by
Mar 1, 2016
Penalty
Initial $2,000 · Current $0 Reduced
29 CFR 1926.451(g)(4)(ii): The top edge height of top-rails on supported scaffolds exceed the maximum height of 45 inches for scaffolds manufactured and put into service before January 1, 2000 and also for scaffolds manufactured and put into service after January 1, 2000.   a)  At the Northwest side of the building, on the 4th floor deck, on or about 1/5/16:  Employees were working on a supported scaffold where the working level was approximately 8 feet from the deck and approximately 38 feet from ground at the outside edge.  The top-rail of this scaffold was placed approximately 60 inches from the working level.  Abatement certification must be submitted for this item.
Recent events (3)
  • — J (S) $0
  • — C (S) $2000
  • — Z (S) $2000

1926.502 D06 V

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Feb 24, 2016
Abate by
Mar 1, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(6)(v): A snap-hook was connected to an object which is incompatibly shaped or dimensioned in relation to the snaphook such that unintentional disengagement could occur by the connected object being able to depress the snaphook keeper and release itself.  a)  At the Northwest side of the building, on the 4th floor deck, on or about 1/5/16:  Employees were working on a supported scaffold where the working level was approximately 8 feet from the deck and approximately 38 feet from ground at the outside edge.  Workers were wearing personal fall arrest equipment where the anchor that they were attached to was of a type and configuration that was not compatible with the snap-hook.     b)  At the Southwest side of the building, on the 4th floor deck, on or about 1/5/16:  Employees were working on a supported scaffold where the working level was approximately 8 feet from the deck and approximately 38 feet from ground at the outside edge.  Workers were wearing personal fall arrest equipment where the anchor that they were attached to was of a type and configuration that was not compatible with the snap-hook.     Abatement certification must be submitted for this item.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.451 E06 I

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Feb 24, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.451(e)(6)(i): Integral prefabricated scaffold access frames were not specifically designed or constructed for use as ladder rungs:  a)  At the Northwest side of the building, on the 4th floor deck, on or about 1/5/16:  An employee climbed the scaffold frame to access a work platform approximately 8 feet from the deck and approximately 38 feet from ground.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.1053 B13

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Feb 24, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(13), referencing 29 CFR1926.451(e): The top or top step of a stepladder was used as a step:  a)  At the Southwest side of the building, on the 4th floor deck, on or about 1/5/16:  An employee climbed a 6 foot step ladder to access the scaffold plank that was also 6 feet from the deck and where the employee stepped onto the top two levels of the ladder.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.303 B01

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Feb 24, 2016
Abate by
Mar 1, 2016
Penalty
Initial $1,600 · Current $0 Reduced
29 CFR 1926.303(b)(1): Grinding machines were not equipped with safety guards in conformance with the requirements of ANSI B7.1-1970, Safety Code for the Use, Care, and Protection of abrasive wheels, and paragraph (d) of this section.  a)  At the jobsite, on the 4th floor deck, on or about 1/5/16:  Employees were using a hand powered grinder without a guard attached.    Abatement certification must be submitted for this item.