SYRACUSE, NY —
OSHA Inspection: JW INTERIOR AND EXTERIOR WALL SYSTEMS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of JW INTERIOR AND EXTERIOR WALL SYSTEMS in FAIRFIELD INN 6593 WEIGHLOCK DRIVE, SYRACUSE, NY 13201 (NAICS 238130). OSHA activity number 341171452.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- JW INTERIOR AND EXTERIOR WALL SYSTEMS
- Site address
- FAIRFIELD INN 6593 WEIGHLOCK DRIVE
- City
- SYRACUSE
- State
- NY
- ZIP
- 13201
- Mailing
- 6750 PICKARD DRIVE, SYRACUSE, NY 13211
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 16
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.501 B01
- Issued
- Feb 24, 2016
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a) At the jobsite, on the 4th floor deck, on or about 1/5/16: Employees were working in close proximity to the edge of a working surface, approximately 30 feet from ground without fall protection. b) At the jobsite, on the 4th floor deck, on or about 1/5/16: Employees were working in close proximity to the edge of a working surface and an unprotected elevator shaft approximately 30 feet from the lower level, without fall protection.
Recent events (3)
- — J (S) $0
- — C (S) $2800
- — Z (S) $2800
1926.501 B04 I
- Issued
- Feb 24, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights) more than 6 feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around the openings: a) At the jobsite, on the 4th floor deck, on or about 1/5/16: Employees were directly over a hole where the cover had been unsecured and the marking had worn off. b) At the jobsite, on the 4th floor deck, on or about 1/5/16: Employees were working in close proximity to an unprotected hole that was adjacent to an unprotected elevator shaft.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1926.451 G04 II
- Issued
- Feb 24, 2016
- Abate by
- Mar 1, 2016
- Penalty
- Initial $2,000 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(g)(4)(ii): The top edge height of top-rails on supported scaffolds exceed the maximum height of 45 inches for scaffolds manufactured and put into service before January 1, 2000 and also for scaffolds manufactured and put into service after January 1, 2000. a) At the Northwest side of the building, on the 4th floor deck, on or about 1/5/16: Employees were working on a supported scaffold where the working level was approximately 8 feet from the deck and approximately 38 feet from ground at the outside edge. The top-rail of this scaffold was placed approximately 60 inches from the working level. Abatement certification must be submitted for this item.
Recent events (3)
- — J (S) $0
- — C (S) $2000
- — Z (S) $2000
1926.502 D06 V
- Issued
- Feb 24, 2016
- Abate by
- Mar 1, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(d)(6)(v): A snap-hook was connected to an object which is incompatibly shaped or dimensioned in relation to the snaphook such that unintentional disengagement could occur by the connected object being able to depress the snaphook keeper and release itself. a) At the Northwest side of the building, on the 4th floor deck, on or about 1/5/16: Employees were working on a supported scaffold where the working level was approximately 8 feet from the deck and approximately 38 feet from ground at the outside edge. Workers were wearing personal fall arrest equipment where the anchor that they were attached to was of a type and configuration that was not compatible with the snap-hook. b) At the Southwest side of the building, on the 4th floor deck, on or about 1/5/16: Employees were working on a supported scaffold where the working level was approximately 8 feet from the deck and approximately 38 feet from ground at the outside edge. Workers were wearing personal fall arrest equipment where the anchor that they were attached to was of a type and configuration that was not compatible with the snap-hook. Abatement certification must be submitted for this item.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1926.451 E06 I
- Issued
- Feb 24, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(e)(6)(i): Integral prefabricated scaffold access frames were not specifically designed or constructed for use as ladder rungs: a) At the Northwest side of the building, on the 4th floor deck, on or about 1/5/16: An employee climbed the scaffold frame to access a work platform approximately 8 feet from the deck and approximately 38 feet from ground.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1926.1053 B13
- Issued
- Feb 24, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(13), referencing 29 CFR1926.451(e): The top or top step of a stepladder was used as a step: a) At the Southwest side of the building, on the 4th floor deck, on or about 1/5/16: An employee climbed a 6 foot step ladder to access the scaffold plank that was also 6 feet from the deck and where the employee stepped onto the top two levels of the ladder.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1926.303 B01
- Issued
- Feb 24, 2016
- Abate by
- Mar 1, 2016
- Penalty
- Initial $1,600 · Current $0 Reduced
General-duty citation text
29 CFR 1926.303(b)(1): Grinding machines were not equipped with safety guards in conformance with the requirements of ANSI B7.1-1970, Safety Code for the Use, Care, and Protection of abrasive wheels, and paragraph (d) of this section. a) At the jobsite, on the 4th floor deck, on or about 1/5/16: Employees were using a hand powered grinder without a guard attached. Abatement certification must be submitted for this item.
Recent events (3)
- — J (S) $0
- — C (S) $1600
- — Z (S) $1600
More inspections at JW Interior and Exterior Wall Systems
View JW Interior and Exterior Wall Systems's full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341171452.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.