Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SCHNEIDER BROTHERS CORPORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SCHNEIDER BROTHERS CORPORATION in 7371 EASTMAN ROAD, SYRACUSE, NY 13212 (NAICS 332312). OSHA activity number 341173011.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Schneider Brothers Corporation — free Get an email when a new federal OSHA severe-injury report for Schneider Brothers Corporation is published. One employer, no account, unsubscribe in one click.
Site address
7371 EASTMAN ROAD
City
SYRACUSE
State
NY
ZIP
13212
Mailing
7371 EASTMAN ROAD, SYRACUSE, NY 13212
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
19
Ownership type
A

6 citations on file for this inspection.

1910.36 D01

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 5, 2016
Penalty
Initial $1,020 · Current $1,020
29 CFR 1910.36(d)(1): Exit(s) were locked or fastened, preventing free escape from inside the building:    a) Cold Storage Area, on or about 1/14/16: An exit was found to be in a locked position preventing free and unobstructed escape in the event of a fire or other emergency.
Recent events (1)
  • — Z (S) $1020

1910.37 B02

Serious Gravity 1 3 instances 3 exposed
Issued
Apr 5, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "EXIT":    a)  Back Shop Area, on or about 1/14/16:  Exit door near Shear was not marked "EXIT" to indicate its purpose.    b) Cold Storage Area, on or about 1/14/16:  Two exit doors in this area were not marked "EXIT" to indicate their purpose
Recent events (1)
  • — Z (S) $0

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 5, 2016
Penalty
Initial $1,600 · Current $1,600
29 CFR 1910.212(a)(1):  One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created point of operation, rotating parts, and flying chips:      a)  Shop Area, on or about 1/14/16:  Bridgeport Mill was not provided with a chuck and tool guard.
Recent events (1)
  • — Z (S) $1600

1910.219 D01

Serious Gravity 5 2 instances 2 exposed
Issued
Apr 5, 2016
Penalty
Initial $1,600 · Current $1,600
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):  a)  Shop Area, on or about 1/14/16:  The Bridgeport Mill was not provided with a guard over the in-running nip points of the belt and pulley drive.  a)  Cold Storage Area, on or about 1/14/16:  The circulating fan off of the wood stove was not provided with a guard over the in-running nip points of the belt and pulley drive.
Recent events (1)
  • — Z (S) $1600

1910.219 E01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 5, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs 42 inches or less from the floor level were not fully enclosed by guards conforming to requirements specified in 29 CFR 1910.219(m) and (o):  a)  Shop Area, on or about1/14/16:  The Bridgeport Mill was not provided with a guard over the in-running nip points of the belt and pulley drive.
Recent events (1)
  • — Z (S) $0

1910.219 E03 I

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 5, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o):          a)  Cold Storage Area, on or about 1/14/16:  The circulating fan off of the wood stove did not have the incline belt guarded.
Recent events (1)
  • — Z (S) $0

View Schneider Brothers Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341173011.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.