Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BORGWARNER EMISSIONS SYSTEMS LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BORGWARNER EMISSIONS SYSTEMS LLC in 600 HIGHWAY 32 EAST, WATER VALLEY, MS 38965 (NAICS 336350). OSHA activity number 341174761.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Borgwarner Emissions Systems LLC — free Get an email when a new federal OSHA severe-injury report for Borgwarner Emissions Systems LLC is published. One employer, no account, unsubscribe in one click.
Site address
600 HIGHWAY 32 EAST
City
WATER VALLEY
State
MS
ZIP
38965
Mailing
600 HIGHWAY 32 EAST, WATER VALLEY, MS 38965
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336350
Employees
450
Ownership type
A

6 citations on file for this inspection.

1910.147 C07 I

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 17, 2016
Abate by
Apr 8, 2016
Penalty
Initial $3,000 · Current $1,800 Reduced
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that employees acquired the knowledge and skills required for the safe application, usage and removal of energy control devices:  (a) At the facility - On or about January 13, 2016, an employee was performing lockout/tagout on the Parts Washer # WV11586 for the monthly PM and was not trained as an authorized employee.
Recent events (2)
  • — I (S) $1800
  • — Z (S) $3000

1910.151 C

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 17, 2016
Abate by
Apr 8, 2016
Penalty
Initial $3,750 · Current $2,250 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:  (a) At the Ransohoff part washer - On or about January 13, 2016, a quick drenching facility for eyes and body was not in the immediate vicinity where employees were working with a corrosive chemical, Techniclean S 5001, which contains 2-aminoethanol.  Employees were testing the concentration every morning, adding the chemical as needed and performing the monthly PM without a facility for drenching or to flush the eyes and body in the immediate vicinity.
Recent events (2)
  • — I (S) $2250
  • — Z (S) $3750

1910.303 F01

Serious Gravity 1 1 instance 5 exposed
Issued
Mar 17, 2016
Abate by
Mar 25, 2016
Penalty
Initial $2,250 · Current $1,350 Reduced
29 CFR 1910.303(f)(1): Each disconnecting means required by Subpart S of Part 1910 for motors and appliances was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:  (a) In the maintenance shop area - On or about January 13, 2016, there were two disconnects mounted on the wall that were not labeled as to it's purpose;  1) The first one next to the Greenlee maintenance container went to a transformer but there was no indication as to what the transformer supplied.  2) The second disconnect feed into an electrical raceway that feed some receptacles however it was not known where the conduits going to the right and towards the ceiling went to.
Recent events (2)
  • — I (S) $1350
  • — Z (S) $2250

1910.303 F02

Serious Gravity 1 2 instances 4 exposed
Issued
Mar 17, 2016
Abate by
Apr 8, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:  (a) In the facility - On or about January 13, 2016, 18 of the 40 circuit breakers in circuit breaker panel C-E14 were not labeled or marked to indicate its purpose.  (b) In the facility - On or about January 13, 2016, 28 of the 42 circuit breakers in circuit breaker panel W-C17-A were not labeled or marked to indicate its purpose.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C06 I

Other-than-serious 1 instance 14 exposed
Issued
Mar 17, 2016
Abate by
Jun 10, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  (a) At the facility - On or about January 13, 2016, periodic inspections, at least annually, of the energy control procedures for equipment or groups of equipment were not conducted to ensure that the specific procedures were current and were being followed by authorized employees.   1. Lockout/Energy Control Demonstration Checklist for a demonstration/practice machine was used for the periodic inspection and not actual operating equipment. 2. The last demonstration/practice was 10/3/14 which was 15 months.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 G01 II

Other-than-serious 1 instance 4 exposed
Issued
Mar 17, 2016
Abate by
Mar 25, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:  a) In the maintenance shop area - On or about January 13, 2016, the disconnecting panel next to the Greenlee maintenance container and the disconnecting panel that fed to an electrical raceway had materials or equipment stored in front of the panels.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Borgwarner Emissions Systems LLC's full OSHA safety record →