BIG LAKE, TX —
OSHA Inspection: AMERICAN JEREH INTERNATIONAL CORPORATION
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of AMERICAN JEREH INTERNATIONAL CORPORATION in 13437 NORTH HWY 137, BIG LAKE, TX 76932 (NAICS 213112). OSHA activity number 341176964.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AMERICAN JEREH INTERNATIONAL CORPORATION
- Site address
- 13437 NORTH HWY 137
- City
- BIG LAKE
- State
- TX
- ZIP
- 76932
- Mailing
- 7501 MILLER ROAD 2, HOUSTON, TX 77049
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213112
- Employees
- 200
- Ownership type
- A
Citations
6 citations on file for this inspection.
1904.39 A
- Issued
- Jun 21, 2016
- Abate by
- Aug 22, 2016
- Penalty
- Initial $5,400 · Current $2,700 Reduced
General-duty citation text
29 CFR 1904.39(a)(2): Basic Requirement. Within twenty-four (24) hours after the in-patient hospitalization of one or more employees or an employee's amputation or an employee's loss of an eye, as a result of a work-related incident, you must report the in-patient hospitalization, amputation, or loss of an eye to OSHA. The employer did not report the in-patient hospitalization of an employee from a work-related injury within 24 hours to the nearest OSHA area office.
Recent events (2)
- — I (O) $2700
- — Z (S) $5400
1910.157 C01
- Issued
- Jun 21, 2016
- Abate by
- Aug 22, 2016
- Penalty
- Initial $6,300 · Current $3,150 Reduced
General-duty citation text
29 CFR 1910.157(c)(1): The employer did not provide portable fire extinguishers and did not mount, locate, and identify them so that they were readily accessible to employees without subjecting the employees to possible injury: On January 8, 2016, employees performing slurry operations from a steel platform were exposed to burn hazards while working in areas without fire extinguishers.
Recent events (2)
- — I (O) $3150
- — Z (S) $6300
1910.303 B01 I
- Issued
- Jun 21, 2016
- Abate by
- Aug 22, 2016
- Penalty
- Initial $6,300 · Current $3,150 Reduced
General-duty citation text
29 CFR 1910.303(b)(1)(i): Electrical equipment was not free from recognized hazards that would likely cause death or serious physical harm to employees: On January 8, 2016, the employer did not ensure electrical wiring entering into the electrical control panel on the platform was installed with outer sheathing and exposed employees to electrical shock hazards.
Recent events (2)
- — I (S) $3150
- — Z (S) $6300
1910.303 B06
- Issued
- Jun 21, 2016
- Abate by
- Aug 22, 2016
- Penalty
- Initial $6,300 · Current $3,150 Reduced
General-duty citation text
29 CFR 1910.303(b)(6): Conductors or equipment were located in damp or wet locations; where they were exposed to gases, fumes, vapors, liquids, or other agents that had a deteriorating effect on the conductors or equipment; or where exposed to excessive temperatures and were not identified for use in the operating environment: On January 8, 2016, employees performing slurry operations having hyrdrocarbon gases were exposed to electrical shock and fire hazards while working atop a wet steel platform containing exposed electrical wiring.
Recent events (2)
- — I (S) $3150
- — Z (S) $6300
1910.304 G05
- Issued
- Jun 21, 2016
- Abate by
- Aug 22, 2016
- Penalty
- Initial $6,300 · Current $3,150 Reduced
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: On January 8, 2016, employees were exposed to electrical shock, flash fire and explosion hazards while working from a steel platform with an electrical control panel that had exposed wiring without a ground.
Recent events (2)
- — I (S) $3150
- — Z (S) $6300
1910.305 A01 I
- Issued
- Jun 21, 2016
- Abate by
- Aug 22, 2016
- Penalty
- Initial $6,300 · Current $3,150 Reduced
General-duty citation text
29 CFR 1910.305(a)(1)(i): Employer did not ensure metal raceways, cable armor, and other metal enclosures for conductors were not connected to all boxes, fittings, and cabinets to provide effective electrical continuity: On January 8, 2016, employees working from a steel platform that did not have electrical wiring enclosed in a grounded continuous metal raceway were exposed to electrical shock, flash fire and explosion hazards.
Recent events (2)
- — I (S) $3150
- — Z (S) $6300
More inspections in this industry (NAICS 213112)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341176964.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.