On , OSHA opened a referral safety inspection of TINTORIA PIANA, INC. in 220 S. ERWIN STREET, CARTERSVILLE, GA 30120 (NAICS 313310). OSHA activity number 341179398.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TINTORIA PIANA, INC.
- Site address
- 220 S. ERWIN STREET
- City
- CARTERSVILLE
- State
- GA
- ZIP
- 30120
- Mailing
- 220 S. ERWIN, CARTERSVILLE, GA 30120
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 313310
- Employees
- 40
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.147 C02 I
- Issued
- May 27, 2016
- Abate by
- Jun 16, 2016
- Penalty
- Initial $4,900 · Current $2,940 Reduced
General-duty citation text
29 CFR 1910.147(c)(2)(i): Where an energy isolating device was not capable of being locked out, the employer's energy control program under 29 CFR 1910.147(c)(1) did not utilize a tagout system: a) In the Production Area, the employer failed to ensure that a tagout system was utilized during the cleaning of the Bale Press #2 (Gualchierani System SAS Model FTGD 60).
Recent events (2)
- — I (S) $2940
- — Z (S) $4900
1910.147 C04 II B
- Issued
- May 27, 2016
- Abate by
- Jun 16, 2016
- Penalty
- Initial $4,900 · Current $2,940 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy: a) In the Production Area, the employer failed to specifically outline the steps for shutting down, isolate, blocking and securing Bale Press #2 (Gualchierani System SAS Model FTGD 60) to control hazardous energy.
Recent events (2)
- — I (S) $2940
- — Z (S) $4900
1910.147 C06 I
- Issued
- May 27, 2016
- Abate by
- Jun 16, 2016
- Penalty
- Initial $4,900 · Current $2,940 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed: a) In the Production Area, the employer failed to annually review the procedure to ensure that employees were correctly carrying out energy control procedures for Bale Press #2 (Gualchierani System SAS Model FTGD 60).
Recent events (2)
- — I (S) $2940
- — Z (S) $4900
1910.147 C07 I A
- Issued
- May 27, 2016
- Abate by
- Jun 16, 2016
- Penalty
- Initial $4,900 · Current $2,940 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation: (a) In the Production Area the employer failed to provide training on the methods and means necessary for energy isolation to employees operating the Bale Press #2 (Gualchierani System SAS Model FTGD 60). Employees were not trained on the isolation of hydraulic energy.
Recent events (2)
- — I (S) $2940
- — Z (S) $4900
1910.147 C07 IV
- Issued
- May 27, 2016
- Abate by
- Jun 16, 2016
- Penalty
- Initial $4,900 · Current $2,940 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(iv): The employer did not certify that employee training had been accomplished: a) In the Production Area, employees who had been trained on incorrect Lockout Tagout procedures for Bale Press #2 (Gualchierani System SAS Model FTGD 60) did not have their training certified by the employer.
Recent events (2)
- — I (S) $2940
- — Z (S) $4900
More inspections at Tintoria Piana, INC.