Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ATASCOSA STEEL INDUSTRIES INC

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of ATASCOSA STEEL INDUSTRIES INC in 1275 SCHUETTIG RD, POTEET, TX 78065 (NAICS 238120). OSHA activity number 341180743.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Atascosa Steel Industries INC — free Get an email when a new federal OSHA severe-injury report for Atascosa Steel Industries INC is published. One employer, no account, unsubscribe in one click.
Site address
1275 SCHUETTIG RD
City
POTEET
State
TX
ZIP
78065
Mailing
1275 SCHUETTIG RD, POTEET, TX 78065
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
Employees
11
Ownership type
A

3 citations on file for this inspection.

1910.253 B04 I

Serious Gravity 5 1 instance 4 exposed
Issued
May 17, 2016
Abate by
May 25, 2016
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1910.253(b)(4)(i): Oxygen cylinders were stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near other substance likely to cause or accelerate fire; or in an acetylene generator compartment:   CYLINDER STORAGE: On or about January 13, 2016, and at times prior thereto, employees were exposed to the physical hazard of fire and being struck by rupturing compressed gas cylinders from incompatible materials being stored in the fuel and oxygen cylinder storage area.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1910.253 B05 II I

Serious Gravity 5 1 instance 4 exposed
Issued
May 17, 2016
Abate by
May 25, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(5)(ii)(I): Cylinders were not kept far enough away from the actual welding or cutting operation so that sparks, hot slag, or flame would not reach them:  CYLINDER STORAGE: On or about January 13, 2016, and at times prior thereto, employees were exposed to the physical hazard of fire and being struck by rupturing compressed gas cylinders while welding approximately 105 inches (8.75 feet) from the fuel and oxygen cylinder storage area.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.253 B02 IV

Other-than-serious 1 instance 4 exposed
Issued
May 17, 2016
Abate by
May 25, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use:  CYLINDER STORAGE: On or about January 13, 2016, and at times prior thereto, employees were exposed to the physical hazard of fire and being struck by rupturing compressed gas cylinders while working near uncapped, empty oxygen and acetylene fuel cylinders.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341180743.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.