NIXA, MO —
OSHA Inspection: ACCURATE MOLD & PLASTICS CORPORATION INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ACCURATE MOLD & PLASTICS CORPORATION INC. in 202 WEST MOUNT VERNON STREET, NIXA, MO 65714 (NAICS 322220). OSHA activity number 341180982.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ACCURATE MOLD & PLASTICS CORPORATION INC.
- Site address
- 202 WEST MOUNT VERNON STREET
- City
- NIXA
- State
- MO
- ZIP
- 65714
- Mailing
- 202 WEST MOUNT VERNON STREET, NIXA, MO 65714
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 322220
- Employees
- 23
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.242 B
- Issued
- Jan 27, 2016
- Penalty
- Initial $1,200 · Current $0 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: On or about January 12, 2016 at the Accurate Mold and Plastics Corporation facility- employees working at or near the maintenance shop were exposed to possible injuries while using compressed air for cleaning purposes that was not reduced to less than 30 p.s.i. Abatement certification is not required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $1200
1910.303 B01 IV
- Issued
- Jan 27, 2016
- Penalty
- Initial $1,600 · Current $1,960
General-duty citation text
29 CFR 1910.303(b)(1)(iv): Electric equipment was not free from recognized hazards that were likely to cause serious physical harm to employees, such as damaged electrical insulation: On or about January 12, 2016 at the Accurate Mold and Plastics Corporation Facility- employees were exposed to serious injuries due to electrical shock, fire, or burns, in that machine # 18 had a 110V electrical cord and flexible cords were found to be in disrepair with damaged or missing outer insulation, abrasions, and splices made with electrical tape. Abatement certification is not required for this item;
Recent events (2)
- — I (S) $1960
- — Z (S) $1600
1910.305 B01 II
- Issued
- Jan 27, 2016
- Penalty
- Initial $1,600 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: On or about January 12, 2016 at the Accurate Mold and Plastics Corporation Facility- employees were exposed to serious injuries, in that the Electrical extension cord had knock out/unused openings that had not been effectively closed. Abatement certification is not required for this item;
Recent events (2)
- — I (S) $0
- — Z (S) $1600
More inspections in this industry (NAICS 322220)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341180982.