DOUGLAS, AZ —
OSHA Inspection: U.S. FOREST SERVICE,CORONADO NF-DOUGLAS RD
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of U.S. FOREST SERVICE,CORONADO NF-DOUGLAS RD in 1192 WEST SADDLEVIEW ROAD, DOUGLAS, AZ 85607 (NAICS 924120). OSHA activity number 341182624.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- U.S. FOREST SERVICE,CORONADO NF-DOUGLAS RD
- Site address
- 1192 WEST SADDLEVIEW ROAD
- City
- DOUGLAS
- State
- AZ
- ZIP
- 85607
- Mailing
- 1192 WEST SADDLEVIEW ROAD, DOUGLAS, AZ 85607
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 924120
- Employees
- 30
- Ownership type
- D
Citations
8 citations on file for this inspection.
1910.102 A
- Issued
- Apr 7, 2016
- Abate by
- Apr 26, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.102(a): 29 CFR 1910.102(a) In-plant transfer, handling, storage, and/or use of acetylene in cylinders did not comply with the provisions of CGA Pamphlet G-1-2009 ("Acetylene"): (a) Coronado NF-Douglas RD, warehouse/engine bay: On or about January 14, 2016, two acetylene gas cylinders in storage were not secured. (b) Coronado NF-Douglas RD, warehouse/engine bay: On or about January 14, 2016, an acetylene gas cylinders in storage did not have a protective cap in place.
Recent events (1)
- — Z (S) $0
1910.304 F01 IV
- Issued
- Apr 7, 2016
- Abate by
- Apr 26, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.304(f)(1)(iv): Overcurrent devices for circuits rated 600 volts, nominal, or less, were not readily accessible to each employee or authorized building management personnel: (a) Coronado NF-Douglas RD, warehouse/gym: On or about January 14, 2016, circuit breaker panel WH was blocked by a portable fan.
Recent events (1)
- — Z (S) $0
1910.106 D02 I
- Issued
- Apr 7, 2016
- Abate by
- Apr 26, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.106(d)(2)(i): Approved container(s) or portable tank(s) were not used for the storage of flammable or combustible liquids: (a) Coronado NF-Douglas RD, warehouse/Range Management: On or about January 14, 2016, gasoline was stored in unapproved two-compartment fuel/oil (dolmar-style) propylene containers. The standard specification of this container (ANSI/ASTM D-3435-80) was not a recognized test standard under the Nationally Recognized Testing Laboratory (NRTL) Program. The U.S. Forest Service was previously cited for a violation of this occupational safety and health standard which was contained in OSHA inspection number 1061629, citation number 1, item number 1 and was affirmed as a final order on November 20, 2015, with respect to a workplace located at Prescott NF, Willow Administration Site, Prescott AZ.
Recent events (1)
- — Z (R) $0
1910.157 C01
- Issued
- Apr 7, 2016
- Abate by
- Apr 26, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: (a) Coronado NF-Douglas RD, warehouse, recreation cache: On or about January 14, 2016, a 10A:120B:C portable fire extinguisher was located on the concrete floor next to the entry door. The U.S. Forest Service was previously cited for a violation of this occupational safety and health standard which was contained in OSHA inspection number 1061717, citation number 1, item number 2 and was affirmed as a final order on June 17, 2015, with respect to a workplace located at Stanislaus NF, Groveland RD, Groveland, CA.
Recent events (1)
- — Z (R) $0
1910.212 A01
- Issued
- Apr 7, 2016
- Abate by
- May 3, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and automatic start up. (a) Coronado NF-Douglas RD, warehouse/Range Management: On or about January 14, 2016, the chuck on the Sears drill press was not guarded to protect employees from exposure to the rotating parts. The U.S. Forest Service was previously cited for a violation of this occupational safety and health standard which was contained in OSHA inspection number 1061638, citation number 1, item number 5 and was affirmed as a final order on November 20, 2015, with respect to a workplace located at Prescott NF, Verde RD, Camp Verde, AZ.
Recent events (1)
- — Z (R) $0
1910.215 B09
- Issued
- Apr 7, 2016
- Abate by
- Apr 26, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: (a) Coronado NF-Douglas RD, warehouse/range management: On or about January 14, 2016, the distance between the periphery of the abrasive wheel and the tongue guard on the Dewalt DW 758 bench grinder was approximately 3/4 of an inch. (b) Coronado NF-Douglas RD, warehouse/engine bay: On or about January 14, 2016, the distance between the periphery of the abrasive wheel and the tongue guard on the Ace 6-inch bench grinder was approximately 3/4 of an inch. The U.S. Forest Service was previously cited for a violation of this occupational safety and health standard which was contained in OSHA inspection number 982195, citation number 2, item number 4 and was affirmed as a final order on December 19, 2014, with respect to a workplace located at Angeles NF, Valyermo Hot Shots, Valyermo, CA.
Recent events (1)
- — Z (R) $0
1910.303 B02
- Issued
- Apr 7, 2016
- Abate by
- Apr 26, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: (a) Coronado NF-Douglas RD, warehouse/Range Management: On or about January 14, 2016, a Whirlpool refrigerator was plugged into a Belkin relocatable power tap (RPT). The U.S. Forest Service was previously cited for a violation of this occupational safety and health standard which was contained in OSHA inspection number 1061654, citation number 1, item number 2 and was affirmed as a final order on November 20, 2015, with respect to a workplace located at Prescott NF, Chino Valley Ranger District, Chino Valley, AZ.
Recent events (1)
- — Z (R) $0
1910.303 G02 I
- Issued
- Apr 7, 2016
- Abate by
- Apr 26, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by approved cabinets or other forms of approved enclosures, or other means listed under this provision: (a) Coronado NF-Douglas RD, utility closet #17: On or about January 14, 2016 and at time prior thereto, employees were exposed to 120 volts from electrical contactor terminals when they adjusted the timer for outside lighting. The U.S. Forest Service was previously cited for a violation of this occupational safety and health standard which was contained in OSHA inspection number 982175, citation number 1, item number 2 and was affirmed as a final order on December 19, 2014 with respect to a workplace located at Angeles NF, Chileo Fire Station 15, La Canada, CA.
Recent events (1)
- — Z (R) $0
More inspections at U.S. Forest Service,Coronado Nf-Douglas RD
View U.S. Forest Service,Coronado Nf-Douglas RD's full OSHA safety record →
More inspections in this industry (NAICS 924120)
More inspections in AZ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341182624.