MILLERSBURG, OH —
OSHA Inspection: WASTEQUIP LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of WASTEQUIP LLC in 930 MASSILON ROAD, MILLERSBURG, OH 44654 (NAICS 332116). OSHA activity number 341182947.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WASTEQUIP LLC
- Site address
- 930 MASSILON ROAD
- City
- MILLERSBURG
- State
- OH
- ZIP
- 44654
- Mailing
- 930 MASSILON ROAD, MILLERSBURG, OH 44654
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332116
- Employees
- 22
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C04 II D
- Issued
- Feb 25, 2016
- Abate by
- Apr 1, 2016
- Penalty
- Initial $5,500 · Current $3,850 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following: 29 CFR 1910.147(c)(4)(ii)(D): Specific requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures. a. At the workplace in the Betenbender Press Brake area, the employer's lockout procedures for the Betenbender Press Brake did not include a method to verify isolation of electrical energy sources and deenergization of the Betenbender Press Brake.
Recent events (2)
- — I (S) $3850
- — Z (S) $5500
1910.147 C04 II A
- Issued
- Feb 25, 2016
- Abate by
- Apr 1, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following: 29 CFR 1910.147(c)(4)(ii)(A): A specific statement of the intended use of the procedure; a. At the workplace in the Betenbender Press Brake area, the employer's lockout procedures for the Betenbender Press Brake did not include a specific statement of it's intended use.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 332116)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341182947.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.