Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MAPLEHURST BAKERIES, LLC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of MAPLEHURST BAKERIES, LLC. in 299 PEPSI RD., MANCHESTER, NH 03109 (NAICS 311812). OSHA activity number 341183010.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Maplehurst Bakeries, LLC. — free Get an email when a new federal OSHA severe-injury report for Maplehurst Bakeries, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
299 PEPSI RD.
City
MANCHESTER
State
NH
ZIP
03109
Mailing
299 PEPSI RD., MANCHESTER, NH 03109
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311812
Employees
275
Ownership type
A

9 citations on file for this inspection.

1910.23 C01

Serious Gravity 10 20 instances 4 exposed
Issued
Feb 24, 2016
Abate by
Mar 1, 2016
Penalty
Initial $7,000 · Current $3,500 Reduced
29 CFR 1910.23(c)(1): Open-sided floor(s) or platform(s) 4 feet (1.22 m) or more above the adjacent floor or ground level were not guarded by standard railings (or the equivalent as specified in 29 CFR 1910.23(e)(3)(i) through (v)), on all open sides:    a. Ovens Room - On or about January 12, 2016, the employer failed to provide fall protection to employees assigned maintenance duties while working from the roof of the ovens and exposes to falls of over 7 feet.
Recent events (2)
  • — I (S) $3500
  • — Z (S) $7000

1910.37 A02

Serious Gravity 1 1 instance 5 exposed
Issued
Feb 24, 2016
Penalty
Initial $3,000 · Current $1,500 Reduced
29 CFR 1910.37(a)(2): Exit routes were not arranged so that employees did not have to travel toward a high hazard area:    a. Maintenance Shop - On or about January 12, 2016, flammable gases cylinders were stored in the emergency exit route.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $3000

1910.147 C04 I

Serious Gravity 10 1 instance 2 exposed
Issued
Feb 24, 2016
Abate by
Mar 1, 2016
Penalty
Initial $7,000 · Current $7,000
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  a. Waukesha pump - On or about January 12, 2016, the employer failed to implement and enforce a lockout tagout procedure specifically designed for the Waukesha pump, to include the manufacturer's requirements of deenergizing and locking out the pump prior to allowing maintenance or cleaning procedures.
Recent events (2)
  • — I (S) $7000
  • — Z (S) $7000

1910.147 D03

Serious Gravity 10 1 instance 2 exposed
Issued
Feb 24, 2016
Abate by
Mar 1, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(3): All energy isolating devices that are needed to control the energy to the machine or equipment was not physically located and operated in such a manner as to isolate the machine or equipment from the energy sources:  a. Waukesha pump - On or about January 5, 2016, a competent person did not physically locate and isolate all energy sources to the pump prior to allowing the cleaning procedures to begin.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 10 3 instances 7 exposed
Issued
Feb 24, 2016
Abate by
Mar 1, 2016
Penalty
Initial $7,000 · Current $3,500 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    Instance a. Dispensing area - On or about January 12, 2016, the conveyor belts in-running nip point was not guarded to prevent employees' amputation hazards.    Instance b. Icing area - On or about January 12, 2016, the conveyor belt's rotating shaft was not guarded to prevent accidental contact by employees assigned to work at this station.    Instance c. Maintenance shop - On or about January 12, 2016, the Enco (S/N 0287) lathe machine was not guarded at the lead screw.
Recent events (2)
  • — I (S) $3500
  • — Z (S) $7000

1910.242 B

Serious Gravity 1 2 instances 7 exposed
Issued
Feb 24, 2016
Abate by
Mar 1, 2016
Penalty
Initial $3,000 · Current $1,500 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i. and effective chip guarding and personal protective equipment was not used:    Instance a. Icing Area - On or about January 12, 2016, the compressed air utilized for cleaning purposes was set at 85 PSI.     Instance b. Dispensing Area - On or about January 12, 2016, the compressed air utilized for cleaning purposes was set at 85 PSI.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $3000

1910.157 C01

Other-than-serious 1 instance 4 exposed
Issued
Feb 24, 2016
Abate by
Mar 1, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  a. Shipping and Receiving - On or about January 12, 2016, the fire extinguisher was not properly maintained to ensure that it was mounted and identified in its designated location.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.212 B

Other-than-serious 1 instance 3 exposed
Issued
Feb 24, 2016
Abate by
Mar 1, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.212(b): Anchoring fixed machinery. Machines designed for a fixed location shall be securely anchored to prevent walking or moving:  a. Maintenance shop - On or about January 12, 2016, the Dayton (model 6Y001A) belt and disc sander was not securely anchored to the floor to prevent walking or movement during the operation of the sander.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.253 B05 II D

Other-than-serious 1 instance 6 exposed
Issued
Feb 24, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(5)(ii)(D): Cylinders were not secured on a special truck, regulators were not removed and valve protection caps, when provided for, were not put in place before cylinders were moved:  a. Maintenance Shop - On or about January 12, 2015, the oxygen and gas cylinders were not secured to the welding cart to prevent them from being knocked over and damaged.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Maplehurst Bakeries, LLC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341183010.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.