FORT MYER, VA —
OSHA Inspection: SUMMIT CONSTRUCTION INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SUMMIT CONSTRUCTION INC. in 523 CARPENTER ROAD, FORT MYER, VA 22211 (NAICS 236220). OSHA activity number 341183838.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SUMMIT CONSTRUCTION INC.
- Site address
- 523 CARPENTER ROAD
- City
- FORT MYER
- State
- VA
- ZIP
- 22211
- Mailing
- 120 COMMERICAL PARKWAY, SANTA ROSA BEACH, FL 32459
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 7
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.350 F04
- Issued
- Mar 4, 2016
- Penalty
- Initial $2,380 · Current $1,785 Reduced
General-duty citation text
29 CFR 1926.350(f)(4): A hose which has been subjected to flashback, or which shows evidence of severe wear or damage, was not tested to twice the normal pressure to which it was subjected, but in no case less than 300 p.s. i. : a) Fort Myer Commissary Refrigeration Upgrade: On or about 01/13/2016, oxygen and acetylene hoses used in soldering copper pipes were not tested to at least 300 psi after repairs were made as a result employees were exposed to possible burns. No abatement certification or documentation required.
Recent events (2)
- — I (S) $1785
- — Z (S) $2380
1926.350 J
- Issued
- Mar 4, 2016
- Penalty
- Initial $2,023 · Current $1,517 Reduced
General-duty citation text
29 CFR 1926.350(j): Section 3.5.3.2d American National Standards Institute Z49.1-1967 as adopted by 29 CFR 1926.350(j): Flash-back protection was not provided by an approved device that will prevent flame from passing into the fuel-gas system. a) Fort Myer Commissary Refrigeration Upgrade: On or about 01/13/2016, acetylene gas used in soldering copper pipes was not provided with flashback protection as a result employees were exposed to possible burns. No abatement certification or documentation required.
Recent events (2)
- — I (S) $1517.25
- — Z (S) $2023
1926.501 B03
- Issued
- Mar 4, 2016
- Penalty
- Initial $2,529 · Current $1,897 Reduced
General-duty citation text
29 CFR 1926.501(b)(3): Each employee in a hoist area was not protected from falling 6 feet (1.8m) or more to lower levels by guardrail systems or personal fall arrest systems: a) Fort Myer Commissary Refrigeration Upgrade: On or about 01/13/2016, employees standing in the hoist area after loading were not provided with fall protection as a result employees were exposed to possible 20' fall. No abatement certification or documentation required.
Recent events (2)
- — I (S) $1896.75
- — Z (S) $2529
More inspections at Summit Construction INC.
View Summit Construction INC.'s full OSHA safety record →
More inspections in this industry (NAICS 236220)
More inspections in VA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341183838.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.