Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: EMZ SOLUTIONS, LLC.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of EMZ SOLUTIONS, LLC. in 535 FLUSHING AVENUE, BROOKLYN, NY 11215 (NAICS 238140). OSHA activity number 341183903.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch EMZ Solutions, LLC. — free Get an email when a new federal OSHA severe-injury report for EMZ Solutions, LLC. is published. One employer, no account, unsubscribe in one click.
Establishment
EMZ SOLUTIONS, LLC.
Site address
535 FLUSHING AVENUE
City
BROOKLYN
State
NY
ZIP
11215
Mailing
528 FAIRWAY DRIVE, WOODMERE, NY 11598
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
5
Ownership type
A

4 citations on file for this inspection.

1926.20 B02

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 29, 2016
Abate by
Apr 15, 2016
Penalty
Initial $2,800 · Current $2,000 Reduced
29 CFR 1926.20(b)(2): Frequent and regular inspections of the job site, materials, and equipment to be conducted by a competent person designated by the employer was not provided by the employer who was responsible to initiate and maintain an accident prevention program:    a- Elevator shaft/roof - 535 Flushing Avenue, Brooklyn NY: A competent person did not conduct frequent and regular inspections of the jobsite.  Employees on this site were exposed to hazards including, but not limited to fall hazards.  Condition noted on or about 01/12/16.    NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $2800

1926.451 F07

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 29, 2016
Abate by
Apr 15, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person.    a- Elevator shaft/roof - 535 Flushing Avenue, Brooklyn NY: A competent person did supervise or direct the scaffold's erection, alteration, etc. Employees on this site were exposed to hazards including but not limited to fall hazards when working from a prefabricated, tubular, welded framed scaffold that was missing mid/top rails, end stops, etc.  Condition noted on or about 01/12/16.    NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 G01 VII

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 29, 2016
Abate by
Apr 6, 2016
Penalty
Initial $2,800 · Current $2,000 Reduced
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.      a- Roof - 535 Flushing Avenue, Brooklyn NY: On or about 01/12/16 an employee working from the outrigger and top of a prefabricated, tubular, welded framed scaffold's third buck (top) that was missing top/midrails as well as endstops was exposed to fall hazards (in excess of 19 feet to the floor below) when performing masonry and other related activities.      NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM.  FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $2800

1926.502 D11

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 29, 2016
Abate by
Apr 6, 2016
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1926.502(d)(11): Lifelines were not protected against being cut or abraded:    a- Roof/Elevator Shaft - 535 Flushing Avenue, Brooklyn NY: On or about 01/12/16 an employee working from the top buck of a tubular welded framed scaffold was exposed to fall hazards, in excess of 19 feet to the ground surface below, when one end of their full body harness's lifeline was attached/wrapped around the unprotected edges of a steel eyebeam.        NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM.  FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2800

View EMZ Solutions, LLC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341183903.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.