Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,892Inspections Most recent open 2026-09-03 Last loaded 2026-09-07

OSHA Inspection: SKYLINE SCAFFOLDING GROUP, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SKYLINE SCAFFOLDING GROUP, INC. in 420 KENT AVENUE, BROOKLYN, NY 11249 (NAICS 238990). OSHA activity number 341184125.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Skyline Scaffolding Group, INC. for free Get an email when a new federal OSHA severe-injury report for Skyline Scaffolding Group, INC. is published. One employer, no account, unsubscribe in one click.
Site address
420 KENT AVENUE
City
BROOKLYN
State
NY
ZIP
11249
Mailing
181 COIT STREET, IRVINGTON, NJ 07111
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238990
Employees
20
Ownership type
Private (A)

3 citations on file for this inspection.

1926.451 E06 VI

Serious Gravity 10 1 instance 2 exposed
Issued
Apr 12, 2016
Penalty
Initial $3,080 · Current $3,080
29 CFR 1926.451(e)(6)(vi): 1926.451(e)(6)(vi):  Integral prefabricated scaffold access frames being used for access had a spacing greater than 16 3/4 inches.  a- 420 Kent Avenue, Brooklyn NY: On or about 1/11/16, employees moving planks to upper levels of a prefabricated, tubular, welded framed scaffold system, and other related activities were exposed to falls (in excess of 25 feet to the ground surface below) when using the side opening in the scaffold's endframes to access and egress the walking/working surfaces.
Recent events (1)
  • · Z (S) $3080

1926.451 E09 IV

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 12, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.451(e)(9)(iv): Cross braces on tubular welded frame scaffolds were used as a means of access or egress.  a- 420 Kent Avenue, Brooklyn NY: On or about 1/11/16, an employee was exposed to falls (in excess of 25 feet to the ground surface below) when accessing the top level of a prefabricated, tubular, welded framed scaffold by standing/climbing on the cross braces.
Recent events (1)
  • · Z (S) $0

1926.451 G01 VII

Serious Gravity 10 1 instance 2 exposed
Issued
Apr 12, 2016
Penalty
Initial $3,080 · Current $3,080
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.   a- 420 Kent Avenue, Brooklyn NY: On or about 1/11/16, company employees moving planks to upper levels of a prefabricated, tubular, welded framed scaffold system, and other related activities were exposed to falls in excess of 25 feet to the ground surface below when they were wearing full body harnesses with the lanyards attached back to the harness rather than to a proper tie off point(s).
Recent events (1)
  • · Z (S) $3080

View Skyline Scaffolding Group, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341184125.