Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PRINTGRAPHICS LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of PRINTGRAPHICS LLC in 1170 INDUSTRIAL PARK DR., VANDALIA, OH 45377 (NAICS 323111). OSHA activity number 341186708.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Printgraphics LLC — free Get an email when a new federal OSHA severe-injury report for Printgraphics LLC is published. One employer, no account, unsubscribe in one click.
Establishment
PRINTGRAPHICS LLC
Site address
1170 INDUSTRIAL PARK DR.
City
VANDALIA
State
OH
ZIP
45377
Mailing
1170 INDUSTRIAL PARK DR., VANDALIA, OH 45377
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
323111
Employees
25
Ownership type
A

7 citations on file for this inspection.

1910.147 C04 II

Deleted Serious Gravity 10 1 instance 6 exposed
Issued
Feb 10, 2016
Abate by
Mar 1, 2016
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1910.147(c)(4)(ii): The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following:  The specific energy control procedure for the Sanden CIT & MPIT Press Machine did not address the magnitudes of the energy sources and the correct way to isolate and affix the energy isolating device to the pneumatic energy source, and how to verify the isolation of the hazardous energy sources.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2800

1910.147 C06 I

Deleted Serious Gravity 5 1 instance 6 exposed
Issued
Feb 10, 2016
Abate by
Mar 1, 2016
Penalty
Initial $1,700 · Current $0 Reduced
29 CFR 1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.  The employer conducted periodic inspection on the Prime UV, UV#2 on the Sanden Printing Machine on July 22, 2015 by an authorized employee was inadequate in that the inspection did not ensure that all hazardous energy sources were isolated and energy isolating devices affixed prior to the start of the servicing and maintenance activity.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1700

1910.147 C07 I A

Serious Gravity 5 1 instance 6 exposed
Issued
Feb 10, 2016
Abate by
Mar 1, 2016
Penalty
Initial $1,700 · Current $1,700
29 CFR 1910.147(c)(7)(i)(A): Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.    The training provided to authorized employees was inadequate in that lockout hardware in conjunction with a lock for a pneumatic ball valve was unavailable to authorized employees to affix onto a pneumatic ball value of the Sanden Press Machine and other machines with pneumatic energy sources.
Recent events (2)
  • — I (S) $1700
  • — Z (S) $1700

1910.147 E02 I

Serious Gravity 5 1 instance 6 exposed
Issued
Feb 10, 2016
Abate by
Mar 1, 2016
Penalty
Initial $1,700 · Current $0 Reduced
29 CFR 1910.147(e)(2)(i): The work area shall be checked to ensure that all employees have been safely positioned or removed.    Employees were not standing clear during positioning.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1700

1910.147 D

Deleted Serious Gravity 10 1 instance 6 exposed
Issued
Feb 10, 2016
Abate by
Mar 1, 2016
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1910.147(d): Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence:   On or about January 12, 2016, in the Production Area, in the rear of the Sanden Press Machine, Offset #7, Press Operators were not required to:   (1) know the type and magnitude of the energy, the hazards of the energy to be controlled, and the method or means to control the energy (2) turn off and shut down the machine (3) physical locate and operate energy isolating devices  in such a manner as to isolate the machine from the energy source (4) affix lockout device to each energy isolating device (5) prior to starting work on machines that have been locked out, verify that isolation and deenergization of the machine have been accomplished.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2800

1910.147 F01 II

Deleted Serious Gravity 10 1 instance 6 exposed
Issued
Feb 10, 2016
Abate by
Mar 1, 2016
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1910.147(f)(1)(ii): Remove employees from the machine or equipment area in accordance with paragraph (e)(2) of this section;  On or about January 12, 2016 at around 1:15 pm in the Production Area at the Sanden Press Machine, a Press Operator was exposed to an amputation hazard when he did not remove a part of his right ring finger from the gears in Offset #7 while another employee turned the switch out and in to see if the roller would turn.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2800

1910.303 B08 I

Other-than-serious 1 instance 6 exposed
Issued
Feb 10, 2016
Penalty
Initial $1,020 · Current $510 Reduced
29 CFR 1910.303(b)(8)(i): Electric equipment shall be firmly secured to the surface on which it is mounted.  Note to paragraph (b)(8)(i) of this section: Wooden plugs driven into holes in masonry, concrete, plaster, or similar materials are not considered secure means of fastening electric equipment.    In the rear of the Sanden Press Machine, Offset #7, an employee was exposed to an electric shock hazard when a 110 Volt AC two receptacle outlet box was free hanging and not mounted.
Recent events (2)
  • — I (O) $510
  • — Z (S) $1020

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341186708.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.