Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: LABORATORY CORPORATION OF AMERICA

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of LABORATORY CORPORATION OF AMERICA in 1 FOREST PARKWAY, SHELTON, CT 06484 (NAICS 621511). OSHA activity number 341186997.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Laboratory Corporation of America — free Get an email when a new federal OSHA severe-injury report for Laboratory Corporation of America is published. One employer, no account, unsubscribe in one click.
Site address
1 FOREST PARKWAY
City
SHELTON
State
CT
ZIP
06484
Mailing
5610 W. LASALLE ST., TAMPA, FL 33607
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
621511
Employees
75
Ownership type
A

7 citations on file for this inspection.

1910.106 F01 I

Other-than-serious 1 instance 15 exposed
Issued
Jun 1, 2016
Penalty
Initial $1,823 · Current $900 Reduced
29 CFR 1910.106(f)(1)(i): Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C). Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), were not stored in closed containers, or in storage tanks above ground outside of buildings, or underground in accordance with paragraph (b) of this section:    Location:  Flammable Store Cabinets, Histology Laboratory, 1 Forest Parkway, Shelton CT, 06484.      A 50 gallon plastic drum of Pharmco-AAPER Reagent Alcohol 200 Proof, a category 2 flammable liquid with a flashpoint of 14 °C / 57 °F, was not closed while in a flammable storage cabinet.
Recent events (2)
  • — I (O) $900
  • — Z (S) $1823

1910.138 B

Other-than-serious 1 instance 25 exposed
Issued
Jun 1, 2016
Abate by
Aug 17, 2016
Penalty
Initial $3,038 · Current $3,038
29 CFR 1910.138(b): The employer did not base selection of appropriate hand protection on an evaluation of the performance characteristics of the hand protection relative to the tasks to be performed, conditions present, duration of use, and the hazards and potential hazards identified:    Location: 1 Forest Parkway, Shelton Ct, 06484.  Histology Laboratory Hematoxylin Staining Area.    An adequate selection of appropriate hand protection based upon the tasks to be performed, conditions present, duration of use, suitable chemical resistance, durability and the hazards and potential hazard identified during the slide preparation procedure was not conducted.
Recent events (2)
  • — I (O) $3038
  • — Z (S) $3038

1910.1450 E03 II

Other-than-serious 1 instance 25 exposed
Issued
Jun 1, 2016
Abate by
Aug 17, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.1450(e)(3)(ii): The Chemical Hygiene Plan did not include the criteria that the employer would use to determine and implement control measures to reduce employee exposure to hazardous chemicals including engineering controls, the use of personal protective equipment and hygiene practices:    Location: Histology Laboratory Hematoxylin Staining Area, 1 Forest Parkway, Shelton CT, 06484    Engineering controls to prevent employees from submerging gloved fingers into xylene baths were not contained within the chemical hygiene plan.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.106 D03 II

Deleted Other-than-serious 1 instance 60 exposed
Issued
Jun 1, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.106(d)(3)(ii): Storage cabinet(s) for flammable liquids were not designed or constructed to meet minimal fire resistance as required:  Location:  Histology Laboratory Flammable Store Cabinets, 1 Forest Parkway, Shelton CT, 06484  The doors on the flammable storage cabinet immediately next to the special staining area did not close properly and adequately in order to create a tight seal with the body of the flammable storage cabinet.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1026 D02 I

Other-than-serious 1 instance 25 exposed
Issued
Jun 1, 2016
Abate by
Oct 31, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.1026(d)(2)(i): The employer did not perform initial monitoring to determine the 8-hour time-weighted average exposure to chromium (VI) for each employee on the basis of a sufficient number of personal breathing zone air samples to accurately characterize full shift exposure on each shift, for each job classification, in each work area:    Location: Histology Laboratory Special Staining Area, 1 Forest Parkway, Shelton CT, 06484    An initial monitoring to determine the 8 hours time-weighed average exposure to chromium (VI) levels along with objective data to ensure chromium (VI) levels were below the action level was not conducted.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1450 D01

Other-than-serious 1 instance 25 exposed
Issued
Jun 1, 2016
Abate by
Oct 31, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.1450(d)(1): The employer did not measure the laboratory employee's exposure to a substance regulated by a standard which required monitoring when there was reason to believe that exposure levels for that substance routinely exceeded the action level or in the absence of an action level, the permissible exposure limit.    Location: Histology Laboratory Special Staining Area, 1 Forest Parkway, Shelton CT, 06484    Initial monitoring to determine chromium (VI) levels along with objective data to ensure chromium (VI) levels were below the action level was not conducted.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1026 J01 I

Other-than-serious 1 instance 2 exposed
Issued
Jun 1, 2016
Abate by
Jun 27, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.1026(j)(1)(i): The employer did not ensure that all surfaces were maintained as free as practicable of accumulations of chromium (VI):  Location: Histology Laboratory Special Staining Area, 1 Forest Parkway, Shelton CT, 06484  Surfaces including but not limited to the hood #4 had detectable levels of chromium present.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Laboratory Corporation of America's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341186997.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.