Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PURRFECT ENTERPRISES, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of PURRFECT ENTERPRISES, INC. in 262 CLINTON STREET, PATERSON, NJ 07522 (NAICS 812320). OSHA activity number 341187003.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Purrfect Enterprises, INC. — free Get an email when a new federal OSHA severe-injury report for Purrfect Enterprises, INC. is published. One employer, no account, unsubscribe in one click.
Site address
262 CLINTON STREET
City
PATERSON
State
NJ
ZIP
07522
Mailing
262 CLINTON STREET, PATERSON, NJ 07522
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
812320
Employees
39
Ownership type
A

7 citations on file for this inspection.

1910.147 C01

Serious Gravity 10 1 instance 3 exposed
Issued
May 23, 2016
Abate by
Aug 11, 2016
Penalty
Initial $4,900 · Current $2,940 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:       a. Facility: Employer did not establish an energy control procedure for an employee's performing services on equipment such as but not limited to American Super Sylon Ironer machines, Uni-Mac Washer, Smith Grantham Laundry and Lavatec Washing machine, on or about 1/20/2016.
Recent events (2)
  • — I (S) $2940
  • — Z (S) $4900

1910.157 C01

Serious Gravity 5 2 instances 3 exposed
Issued
May 23, 2016
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  a) Ironer Machines Area: Portable fire extinguishers were not in their designated location and readily available for use by employees, on or about 1/20/2016.   b) Machine Shop Area: Portable fire extinguishers were not in their designated location and readily available for use by employees, on or about 1/20/2016.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1910.264 D02 I A

Serious Gravity 10 3 instances 3 exposed
Issued
May 23, 2016
Penalty
Initial $4,900 · Current $2,940 Reduced
29 CFR 1910.264(d)(2)(i)(a): Operating Rules, Mechanical, Safety Guards.  No safeguard, safety appliance, or device attached to, or forming an integral part of any machinery shall be removed or made ineffective except for the purpose of making immediate repairs or adjustments. Any such safeguard, safety appliance, or device removed or made ineffective during the repair or adjustment of such machinery shall be replaced immediately upon the completion of such repairs or adjustments.   a. Sheet Ironer Area: Employees operating a ironer machine #1 were exposed to an amputation hazard from an unguarded belt, on or about 1/20/2016.  b. Sheet Ironer Area: Employees operating a ironer machine # 2 were exposed to an amputation hazard from an unguarded belt, on or about 1/20/2016.  c. Tunnel Washer Area: Employees operating a Lavatec tunnel washer machine were exposed to an amputation hazard from an unguarded belt, on or about 5/12/2016.
Recent events (2)
  • — I (S) $2940
  • — Z (S) $4900

1910.303 B02

Serious Gravity 1 2 instances 2 exposed
Issued
May 23, 2016
Penalty
Initial $2,100 · Current $1,260 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  a. Conveyor Area: Quad box was used as an extension cord for a Microwave, on or about 1/20/2016.   b. Conveyor Area: Quad box was used as an extension cord for a portable light, on or about 3/17/2016.
Recent events (2)
  • — I (S) $1260
  • — Z (S) $2100

1910.304 G05

Serious Gravity 5 1 instance 1 exposed
Issued
May 23, 2016
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:   a. Conveyor Area: The ground pins were missing on two extension cords, on or about 3/17/2016.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1910.305 B01 I

Serious Gravity 5 3 instances 2 exposed
Issued
May 23, 2016
Penalty
Initial $3,500 · Current $2,100 Reduced
29 CFR 1910.305(b)(1)(i): Openings through which conductors entered cutout boxes, cabinets, or fittings were not effectively closed:   a. Production Manager Office:  An employee was exposed to an electrical shock and burns from the unused opening on an electrical outlet that was missing a cover, on or about 1/20/2016.   b. Conveyor Area:  An employee was exposed to an electrical shock and burns from the unused opening on an electrical outlet that was missing a cover, on or about 3/17/2016.   c. Conveyor Area:  An employee was exposed to an electrical shock and burns from the unused opening on an electrical outlet that was missing a knockout, on or about 3/17/2016.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

1910.305 G01 IV A

Serious Gravity 1 2 instances 2 exposed
Issued
May 23, 2016
Penalty
Initial $2,100 · Current $1,260 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:   a. Production Manager Office:  A relocatable power tap was used as substitute for permanent wiring to power a computer and printer, on or about 1/20/2016.    b. Conveyor Area:  A relocatable power tap was used as substitute for permanent wiring to power a computer monitor, on or about 3/17/2016.
Recent events (2)
  • — I (S) $1260
  • — Z (S) $2100

View Purrfect Enterprises, INC.'s full OSHA safety record →