PATERSON, NJ —
OSHA Inspection: PURRFECT ENTERPRISES, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of PURRFECT ENTERPRISES, INC. in 262 CLINTON STREET, PATERSON, NJ 07522 (NAICS 812320). OSHA activity number 341187003.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PURRFECT ENTERPRISES, INC.
- Site address
- 262 CLINTON STREET
- City
- PATERSON
- State
- NJ
- ZIP
- 07522
- Mailing
- 262 CLINTON STREET, PATERSON, NJ 07522
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 812320
- Employees
- 39
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.147 C01
- Issued
- May 23, 2016
- Abate by
- Aug 11, 2016
- Penalty
- Initial $4,900 · Current $2,940 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: a. Facility: Employer did not establish an energy control procedure for an employee's performing services on equipment such as but not limited to American Super Sylon Ironer machines, Uni-Mac Washer, Smith Grantham Laundry and Lavatec Washing machine, on or about 1/20/2016.
Recent events (2)
- — I (S) $2940
- — Z (S) $4900
1910.157 C01
- Issued
- May 23, 2016
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: a) Ironer Machines Area: Portable fire extinguishers were not in their designated location and readily available for use by employees, on or about 1/20/2016. b) Machine Shop Area: Portable fire extinguishers were not in their designated location and readily available for use by employees, on or about 1/20/2016.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1910.264 D02 I A
- Issued
- May 23, 2016
- Penalty
- Initial $4,900 · Current $2,940 Reduced
General-duty citation text
29 CFR 1910.264(d)(2)(i)(a): Operating Rules, Mechanical, Safety Guards. No safeguard, safety appliance, or device attached to, or forming an integral part of any machinery shall be removed or made ineffective except for the purpose of making immediate repairs or adjustments. Any such safeguard, safety appliance, or device removed or made ineffective during the repair or adjustment of such machinery shall be replaced immediately upon the completion of such repairs or adjustments. a. Sheet Ironer Area: Employees operating a ironer machine #1 were exposed to an amputation hazard from an unguarded belt, on or about 1/20/2016. b. Sheet Ironer Area: Employees operating a ironer machine # 2 were exposed to an amputation hazard from an unguarded belt, on or about 1/20/2016. c. Tunnel Washer Area: Employees operating a Lavatec tunnel washer machine were exposed to an amputation hazard from an unguarded belt, on or about 5/12/2016.
Recent events (2)
- — I (S) $2940
- — Z (S) $4900
1910.303 B02
- Issued
- May 23, 2016
- Penalty
- Initial $2,100 · Current $1,260 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a. Conveyor Area: Quad box was used as an extension cord for a Microwave, on or about 1/20/2016. b. Conveyor Area: Quad box was used as an extension cord for a portable light, on or about 3/17/2016.
Recent events (2)
- — I (S) $1260
- — Z (S) $2100
1910.304 G05
- Issued
- May 23, 2016
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: a. Conveyor Area: The ground pins were missing on two extension cords, on or about 3/17/2016.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1910.305 B01 I
- Issued
- May 23, 2016
- Penalty
- Initial $3,500 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(i): Openings through which conductors entered cutout boxes, cabinets, or fittings were not effectively closed: a. Production Manager Office: An employee was exposed to an electrical shock and burns from the unused opening on an electrical outlet that was missing a cover, on or about 1/20/2016. b. Conveyor Area: An employee was exposed to an electrical shock and burns from the unused opening on an electrical outlet that was missing a cover, on or about 3/17/2016. c. Conveyor Area: An employee was exposed to an electrical shock and burns from the unused opening on an electrical outlet that was missing a knockout, on or about 3/17/2016.
Recent events (2)
- — I (S) $2100
- — Z (S) $3500
1910.305 G01 IV A
- Issued
- May 23, 2016
- Penalty
- Initial $2,100 · Current $1,260 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a. Production Manager Office: A relocatable power tap was used as substitute for permanent wiring to power a computer and printer, on or about 1/20/2016. b. Conveyor Area: A relocatable power tap was used as substitute for permanent wiring to power a computer monitor, on or about 3/17/2016.
Recent events (2)
- — I (S) $1260
- — Z (S) $2100
More inspections at Purrfect Enterprises, INC.
View Purrfect Enterprises, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 812320)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341187003.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.