ASHLAND, KY —
OSHA Inspection: R AND D ASSOCIATES, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of R AND D ASSOCIATES, INC. in 101 53RD STREET, ASHLAND, KY 41105 (NAICS 336611). OSHA activity number 341187193.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- R AND D ASSOCIATES, INC.
- Site address
- 101 53RD STREET
- City
- ASHLAND
- State
- KY
- ZIP
- 41105
- Mailing
- PO BOX 299, ASHLAND, KY 41105
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336611
- Employees
- 13
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.304 G05
- Issued
- Apr 6, 2016
- Abate by
- May 2, 2016
- Penalty
- Initial $1,600 · Current $960 Reduced
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: a) Barge- On or about 1/20/16, employees were exposed to electrical hazards when the ground prong on an extension cord was missing. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (S) $960
- — Z (S) $1600
1915.73 E
- Issued
- Apr 6, 2016
- Abate by
- Apr 18, 2016
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1915.73(e): When employees were working near the unguarded edges of decks of vessels afloat, they were not protected by personal flotation devices meeting the requirements of 29 CFR 1915.158 (a) Barge - On or about 1/20/16, employees were exposed to water hazards when working from the floating barges without the proper personal flotation devices. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
1915.73 D
- Issued
- Apr 6, 2016
- Abate by
- May 9, 2016
- Penalty
- Initial $4,800 · Current $2,880 Reduced
General-duty citation text
29 CFR 1915.73(d): When employees were exposed to unguarded edges of decks, platforms, flats, or similar flat surfaces, more than 5 feet above a solid surface, the edges were not guarded by adequate guardrails : a) Barge - On or about 1/20/16, employees were exposed to fall hazards when the walkway-platform was not protected by guardrails. b) Platform - On or about 1/20/16, employees were exposed to fall hazards when the platform used to access the barges was not equipped with guardrails. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET). The R and D Associates, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1915.73(d), which was contained in OSHA inspection number 301511549, citation number 1, item number 2b and was affirmed as a final order on 3/3/2011with respect to a workplace located at 100 10th Street, Catlettsburg, KY 41102.
Recent events (2)
- — I (R) $2880
- — Z (R) $4800
1910.305 G02 II
- Issued
- Apr 6, 2016
- Abate by
- May 2, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(ii): Hard-service cord and junior hard-service cord No. 14 and larger were repaired by splicing, which did not retain the insulation, outer sheath properties, and usage characteristics of the cord that was spliced:Note: Hard service flexible cords No. 12 or larger may be spliced if the splice retains the insulation, outer sheath properties, and usage characteristics of the cord being spliced. a) Barge Break Room- On or about 1/20/16, employees were exposed to electrical hazards when power cables were spliced together without retaining the insulating, outer sheath properties and usage characteristics of the cords being spliced In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G02 III
- Issued
- Apr 6, 2016
- Abate by
- May 2, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: (a) Barge - On or about 1/20/16, strain relief was not provided on an extension cord. (b) Break Room- On or about 1/20/16, strain relief was not provided on a heater power cord. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (O) $0
- — Z (O) $0
1915.55 A09
- Issued
- Apr 6, 2016
- Abate by
- May 2, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1915.55(a)(9): Acetylene cylinders were not secured in an upright position. a) Barge- On or about 1/20/16, employees were exposed to struck-by hazards when an acetylene cylinder was not secured to prevent from tipping over. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (O) $0
- — Z (O) $0
1915.81 A01
- Issued
- Apr 6, 2016
- Abate by
- Apr 14, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1915.81(a)(1): The employer did not eliminate slippery conditions, such as snow and ice, on walkways and working surfaces. a) Deck Barge, - On or about 1/20/2016, employees were exposed to slip hazards when slippery conditions were not removed from work surfaces. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 336611)
More inspections in KY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341187193.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.