EMMETT, ID —
OSHA Inspection: MANUFACTURED AND MODULAR AXLE AND TIRE
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of MANUFACTURED AND MODULAR AXLE AND TIRE in 444 HIGHWAY 16 SUITE 112, EMMETT, ID 83617 (NAICS 453930). OSHA activity number 341187847.
Where did this inspection happen?
- Establishment
- MANUFACTURED AND MODULAR AXLE AND TIRE
- Site address
- 444 HIGHWAY 16 SUITE 112
- City
- EMMETT
- State
- ID
- ZIP
- 83617
- Mailing
- P.O.BOX 267, PLATTEVILLE, CO 80651
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 453930
- Employees
- 3
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.37 A03
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $2000.00
General-duty citation text
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed: a) Shop Area: On or about January 20, 2016 and at times prior, employees were exposed working while exit routes were obstructed by materials including axles. NOTE: Abatement certification is required for this item.
Recent events (3)
- — A (S) $2000
- — I (S) $1000
- — Z (S) $2000
1910.178 L03
- Issued
- Abate by
- Penalty
- Initial $2400.00 · Current $2400.00
General-duty citation text
29 CFR 1910.178(l)(3): Powered industrial truck operators did not receive initial training regarding operating instructions, warnings, and precautions for the types of truck the operator was authorized to operate: a) On or about January 20, 2016 and at times prior, powered industrial truck operators had not received training as prescribed in 29 CFR 1910.178(l). NOTE: Abatement certification is required for this item.
Recent events (3)
- — A (S) $2400
- — I (S) $1200
- — Z (S) $2400
1910.178 L04 III
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: a) On or about January 20, 2016 and at times prior, individuals were operating a powered industrial truck with expired training which occurred on July 3, 2012 and expired July 3, 2015. NOTE: Abatement certification is required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 Q07
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed in service: a) On or about January 20, 2016 and at times prior, power industrial trucks used in the workplace were not inspected before use. NOTE: Abatement certification is required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.252 A02 VII
- Issued
- Abate by
- Penalty
- Initial $2400.00 · Current $2400.00
General-duty citation text
29 CFR 1910.252(a)(2)(vii): Where practicable, combustible materials were not relocated at least 35 feet (10.7 m) from the cutting or welding operation work site: a) On or about January 20, 2016 and at times prior, employees were welding axles in shop area within 35 feet of diesel fuel, tires, boxes, and other combustible material. NOTE: Abatement certification is required for this item.
Recent events (3)
- — A (S) $2400
- — I (S) $1200
- — Z (S) $2400
1910.252 A02 XIII
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.252(a)(2)(xiii): The employer did not recognize its responsibility for the safe usage of cutting or welding equipment on its property, in accordance with 29 CFR 1910.252 (a)(2)(xiii)(A) through 29 CFR 1910.252(a)(2)(xiii)(D): a) On or about January 20, 2016 and at times prior, employees welding in the shop area had not received training on the hazards and safe operation of welding equipment. NOTE: Abatement certification is required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.334 A02 II
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $2000.00
General-duty citation text
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service: a) On or about January 20, 2016 and at times prior, employees were using an 110v extension cord in the shop that was cut and frayed. b) On or about January 20, 2016 and at times prior, employees were using an 220v extension cord in the shop that was damaged. NOTE: Abatement certification is required for this item.
Recent events (3)
- — A (S) $2000
- — I (S) $1000
- — Z (S) $2000
1910.305 B02 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: a) North shop wall: On or about January 20, 2016 and at times prior, a 120 volt AC 20 amp outlet did not have a faceplate. NOTE: Abatement certification is required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 453930)
PORT BYRON, NY—2026-06-30 00:00:00
AMERICAN HOMES
UNADILLA, NY—2026-06-18 00:00:00
G R ENTERPRISES LIMITED
ROMULUS, MI—2026-06-04 00:00:00
MICHIGAN MOBILE HOME SUPPLY
ROMULUS, MI—2026-06-04 00:00:00
MICHIGAN MOBILE HOME SUPPLY INC
CENTRAL SQUARE, NY—2026-04-29 00:00:00
WHOLESALE HOMES
More inspections in ID
MERIDIAN, ID—2026-07-17 00:00:00
COBRA'S ROOFING LLC
MERIDIAN, ID—2026-07-17 00:00:00
CARRILLO CONSTRUCTION LLC
MERIDIAN, ID—2026-07-17 00:00:00
SEVY BROTHERS CONSTRUCTION LLC
MERIDIAN, ID—2026-07-17 00:00:00
CBH HOMES
BOISE, ID—2026-07-16 00:00:00
RAYMOND MANAGEMENT COMPANY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341187847.