Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CMC STEEL FABRICATORS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CMC STEEL FABRICATORS, INC. in 301 W. FOXSHIRE, HOUSTON, TX 77053 (NAICS 333120). OSHA activity number 341189884.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch CMC Steel Fabricators, INC. — free Get an email when a new federal OSHA severe-injury report for CMC Steel Fabricators, INC. is published. One employer, no account, unsubscribe in one click.
Site address
301 W. FOXSHIRE
City
HOUSTON
State
TX
ZIP
77053
Mailing
15990 NORTH BARKERS LANDING ROAD, HOUSTON, TX 77079
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333120
Employees
35
Ownership type
A

8 citations on file for this inspection.

1910.147 C04 II

Serious Gravity 10 1 instance 1 exposed
Issued
Jun 1, 2016
Abate by
Jun 27, 2016
Penalty
Initial $7,000 · Current $7,000
29 CFR 1910.147(c)(4)(ii): On or about January 20, 2016, the employer's lockout/tagout program pertaining to a Niagra Shearer machine, serial # 30201, failed to specifically identify gravity as a potential source of stored hazardous energy.
Recent events (2)
  • — I (S) $7000
  • — Z (S) $7000

1910.147 C06 I

Serious Gravity 10 1 instance 3 exposed
Issued
Jun 1, 2016
Abate by
Jun 27, 2016
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.147(c)(6)(i): The employer were not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed:        In Warehouse A, the employer did not conduct periodic inspections of the energy control procedure, exposing employees to struck by hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7000

1910.184 D

Serious Gravity 5 1 instance 3 exposed
Issued
Jun 1, 2016
Abate by
Jun 27, 2016
Penalty
Initial $4,000 · Current $3,000 Reduced
29 CFR 1910.184(d): In Warehouse A, building section, the employer failed to remove a defective polyester sling, which if used, could have potentially exposed employees to struck by hazards
Recent events (2)
  • — I (S) $3000
  • — Z (S) $4000

1910.184 I09

Serious Gravity 5 1 instance 3 exposed
Issued
Jun 1, 2016
Penalty
Initial $4,000 · Current $0 Reduced
29 CFR 1910.184(i)(9): Synthetic web sling was not immediately removed from service for having snags, cuts and tears:        At the bundling section of Warehouse A; employees used a polyester sling, exposing employees to struck by hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4000

1910.212 A03 III

Serious Gravity 10 1 instance 2 exposed
Issued
Jun 1, 2016
Penalty
Initial $7,000 · Current $7,000
29 CFR 1910.212(a)(3)(iii): In the warehouse, employees operated a Niagra A 4-1/2 shearing machine #1, serial #301201 that was not adequately guarded, potentially exposing employees to caught in between hazards.
Recent events (2)
  • — I (S) $7000
  • — Z (S) $7000

1910.212 B

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 1, 2016
Abate by
Jun 27, 2016
Penalty
Initial $5,000 · Current $4,000 Reduced
29 CFR 1910.212(b): At the south side of the warehouse, emplyees operated a Niagra A 4-1/2 shearing machine #1, serial #30201 that was not adequately anchored, potentially exposing emplyees to struck by and caught in between hazards.
Recent events (2)
  • — I (S) $4000
  • — Z (S) $5000

1910.305 B01 II

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 1, 2016
Penalty
Initial $5,000 · Current $3,000 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:        At the south side of the building, next to sheer #1, employees used an outlet with an unused opening, exposing employees to electrical hazards.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $5000

1910.305 G02 III

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 1, 2016
Abate by
Jun 27, 2016
Penalty
Initial $5,000 · Current $0 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws:        In warehouse A, Sheer #3, model #A4, serial #28799; a  flexible cord connected to the control panel was not equipped with strain relief, exposing employees to electrical hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5000

View CMC Steel Fabricators, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341189884.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.