On , OSHA opened a complaint safety inspection of ADM CONSTRUCTION, LLC in 8200 SHERIDAN, WESTMINSTER, CO 80003 (NAICS 236118). OSHA activity number 341193241.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch ADM Construction, LLC — free Get an email when a new federal OSHA severe-injury report for ADM Construction, LLC is published. One employer, no account, unsubscribe in one click.
Site address
8200 SHERIDAN
City
WESTMINSTER
State
CO
ZIP
80003
Mailing
7441 CAMATION PLACE, COMMERCE CITY, CO 80022
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236118
Employees
4
Ownership type
A

4 citations on file for this inspection.

1926.20 B02

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 28, 2016
Abate by
May 13, 2016
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1926.20(b)(2):  The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s):         (a)   ADM Construction, LLC, 8200 Sheridan Street, Westminster, CO  80003: On or about January 14th, 2016, the employer had not ensured a competent person inspected the pump jack scaffold system on the South side of the apartment building prior to employee use. The scaffold system was missing guardrails to prevent falls, and bracing on the bottom portion of the three vertical scaffold poles. Condition exposed employees to fall hazards up to an estimated 16 feet.    (b) Prior to permitting employees to remove and install exterior siding from various apartment buildings, a competent person had not conducted an inspection of the worksite to identify overhead hazards requiring the use of hardhats.  Employees were observed working below a pump jack scaffold without hardhats.  Condition exposed employees to struck by hazards.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1926.100 A

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 28, 2016
Abate by
May 13, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns:     (a)   ADM Construction, LLC, 8200 Sheridan, Westminster, CO  80003: On January 14th, 2016, the employer did not ensure hardhards were available and used while employees worked below the pump jack scaffold system. Condition exposed employees to struck by hazards from falling tools and building materials.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 G01

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 28, 2016
Abate by
May 13, 2016
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1926.451(g)(1):  Each employee on a scaffold 10 feet above a lower level was not protected from falling to the lower level:     (a)  ADM Construction, LLC, 8200 Sheridan Westminster, CO  80003: On January 14, 2016 the employer did not ensure employees were protected from fall hazards in that guardrails or other suitable fall protection was not installed on the pump jack scaffold on the south end of the building.  This condition exposed the employees to the hazard of a fall of approximately 16 feet.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1926.452 J02

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 28, 2016
Abate by
May 13, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary:     (a)  ADM Construction, LLC, 8200 Sheridan, Westminster, CO  80003:  On January 14th, 2016, the employer did not ensure the pump jack scaffold used to remove and replace exterior siding was secured at the top and bottom.  None of the three vertical poles were braced at the bottom.  This condition exposed employees to a fall in excess of 16 feet.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341193241.