WESTMINSTER, CO —
OSHA Inspection: ADM CONSTRUCTION, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of ADM CONSTRUCTION, LLC in 8200 SHERIDAN, WESTMINSTER, CO 80003 (NAICS 236118). OSHA activity number 341193241.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ADM CONSTRUCTION, LLC
- Site address
- 8200 SHERIDAN
- City
- WESTMINSTER
- State
- CO
- ZIP
- 80003
- Mailing
- 7441 CAMATION PLACE, COMMERCE CITY, CO 80022
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236118
- Employees
- 4
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.20 B02
- Issued
- Apr 28, 2016
- Abate by
- May 13, 2016
- Penalty
- Initial $1,600 · Current $960 Reduced
General-duty citation text
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s): (a) ADM Construction, LLC, 8200 Sheridan Street, Westminster, CO 80003: On or about January 14th, 2016, the employer had not ensured a competent person inspected the pump jack scaffold system on the South side of the apartment building prior to employee use. The scaffold system was missing guardrails to prevent falls, and bracing on the bottom portion of the three vertical scaffold poles. Condition exposed employees to fall hazards up to an estimated 16 feet. (b) Prior to permitting employees to remove and install exterior siding from various apartment buildings, a competent person had not conducted an inspection of the worksite to identify overhead hazards requiring the use of hardhats. Employees were observed working below a pump jack scaffold without hardhats. Condition exposed employees to struck by hazards.
Recent events (2)
- — I (S) $960
- — Z (S) $1600
1926.100 A
- Issued
- Apr 28, 2016
- Abate by
- May 13, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns: (a) ADM Construction, LLC, 8200 Sheridan, Westminster, CO 80003: On January 14th, 2016, the employer did not ensure hardhards were available and used while employees worked below the pump jack scaffold system. Condition exposed employees to struck by hazards from falling tools and building materials.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 G01
- Issued
- Apr 28, 2016
- Abate by
- May 13, 2016
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold 10 feet above a lower level was not protected from falling to the lower level: (a) ADM Construction, LLC, 8200 Sheridan Westminster, CO 80003: On January 14, 2016 the employer did not ensure employees were protected from fall hazards in that guardrails or other suitable fall protection was not installed on the pump jack scaffold on the south end of the building. This condition exposed the employees to the hazard of a fall of approximately 16 feet.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
1926.452 J02
- Issued
- Apr 28, 2016
- Abate by
- May 13, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary: (a) ADM Construction, LLC, 8200 Sheridan, Westminster, CO 80003: On January 14th, 2016, the employer did not ensure the pump jack scaffold used to remove and replace exterior siding was secured at the top and bottom. None of the three vertical poles were braced at the bottom. This condition exposed employees to a fall in excess of 16 feet.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 236118)