NEW YORK, NY —
OSHA Inspection: INTEGRITY UV168 INC.
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of INTEGRITY UV168 INC. in 341 BROOME STREET, NEW YORK, NY 10013 (NAICS 238990). OSHA activity number 341193373.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- INTEGRITY UV168 INC.
- Site address
- 341 BROOME STREET
- City
- NEW YORK
- State
- NY
- ZIP
- 10013
- Mailing
- 5705 6TH AVENUE, BROOKLYN, NY 11220
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238990
- Employees
- 5
- Ownership type
- A
Citations
9 citations on file for this inspection.
1926.102 A01
- Issued
- Apr 8, 2016
- Abate by
- Apr 14, 2016
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a) At the jobsite, on the first floor, on or about 1/20/16: An employee was using a Bosch Brute Electric Jackhammer to break concrete, without wearing eye or face protection. Abatement documentation must be submitted for this item.
Recent events (3)
- — F (S) $0
- — C (S) $2800
- — Z (S) $2800
1926.403 I02 I
- Issued
- Apr 8, 2016
- Abate by
- Apr 14, 2016
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph: a) At the jobsite, on or about 1/20/16: Workers were in close proximity to live electrical circuits in a electrical breaker panel, without a cover, located on the 1st floor. Abatement documentation must be submitted for this item.
Recent events (3)
- — F (S) $0
- — C (S) $2800
- — Z (S) $2800
1926.404 B01 I
- Issued
- Apr 8, 2016
- Abate by
- Apr 14, 2016
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites: a) At the jobsite, on or about 1/20/16: Workers were using power tools where GFCI protection was not provided at the source and GFCI appliances were not use. Abatement documentation must be submitted for this item.
Recent events (3)
- — F (S) $0
- — C (S) $2800
- — Z (S) $2800
1926.405 G02 III
- Issued
- Apr 8, 2016
- Abate by
- Apr 14, 2016
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1926.405(g)(2)(iii): Flexible cords were not used in continuous lengths without splice or tap: a) At the jobsite, in the basement, on or about 1/20/16: Workers were using power tools where power was supplied by an extension cord that was spliced. Abatement documentation must be submitted for this item.
Recent events (3)
- — F (S) $0
- — C (S) $2800
- — Z (S) $2800
1926.501 B04 I
- Issued
- Apr 8, 2016
- Abate by
- Apr 14, 2016
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes more than 6 feet above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes. a) At the jobsite, on the first floor, on or about 1/20/16: Employees were working in close proximity to an opening that was used to access and egress that floor with a ladder to and from the basement level, approximately 8 feet below. Abatement documentation must be submitted for this item.
Recent events (3)
- — F (S) $0
- — C (S) $2800
- — Z (S) $2800
1926.502 I04
- Issued
- Apr 8, 2016
- Abate by
- Apr 14, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(i)(4): All covers were not color coded or marked with the word "HOLE" or "COVER" to provide warning of the hazard: a) At the jobsite, on the first floor, on or about 1/20/16: Employees were working in close proximity to a hole and cover where that cover was not marked. Abatement certification must be submitted for this item.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1926.1053 B04
- Issued
- Apr 8, 2016
- Abate by
- Apr 14, 2016
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: a) At the jobsite, in the basement, on or about 1/20/16: Employees were using an 8 foot step ladder to access and egress the first floor where that ladder was leaned against the wall and did not have the spreaders open and locked as its design would dictate. Abatement documentation must be submitted for this item.
Recent events (3)
- — F (S) $0
- — C (S) $2800
- — Z (S) $2800
1926.1053 B01
- Issued
- Apr 8, 2016
- Abate by
- Apr 14, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet: a) At the jobsite, in the basement, on or about 1/20/16: Employees were using an 8 foot step ladder to access and egress the first floor where that ladder did not extend at least 3 feet above the upper landing. Abatement documentation must be submitted for this item.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1926.1053 B13
- Issued
- Apr 8, 2016
- Abate by
- Apr 14, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: a) At the jobsite, in the basement, on or about 1/20/16: Employees were using an 8 foot step ladder to access and egress the first floor where that ladder did not extend at least 3 feet above the upper landing and where employees used the top level of the stepladder. Abatement documentation must be submitted for this item.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0