Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: U.S. GEOLOGICAL SURVEY, HAMMOND BAY BIOLOGICAL STATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of U.S. GEOLOGICAL SURVEY, HAMMOND BAY BIOLOGICAL STATION in 11188 RAY ROAD, MILLERSBURG, MI 49759 (NAICS 921110). OSHA activity number 341193423.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. Geological Survey, Hammond BAY Biological Station — free Get an email when a new federal OSHA severe-injury report for U.S. Geological Survey, Hammond BAY Biological Station is published. One employer, no account, unsubscribe in one click.
Site address
11188 RAY ROAD
City
MILLERSBURG
State
MI
ZIP
49759
Mailing
11188 RAY ROAD, MILLERSBURG, MI 49759
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
921110
Employees
10
Ownership type
D

5 citations on file for this inspection.

1910.37 B02

Serious Gravity 1 2 instances 8 exposed
Issued
Feb 29, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(2) as required by 1960.8(b): Each exit was not clearly visible and marked by a sign reading "Exit":  a. Main Administration building, in the upstairs lakeside office exit leading out of the building was not marked by a sign reading "Exit".  b. In the shop, the exit door leading out of the building was not marked by a sign reading "Exit".
Recent events (1)
  • — Z (S) $0

1910.157 G03

Serious Gravity 1 1 instance 8 exposed
Issued
Feb 29, 2016
Abate by
May 14, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.157(g)(3) as required by 1960.8(b): The employer shall provide employees who have been designated to use fire fighting equipment as part of an emergency action plan with training in the use of the appropriate equipment.  U.S. Geological Survey, Hammond Bay Biological Station, the employer did not provide annual training on portable fire extinguishers that included hands-on training to employees designated to use portable fire extinguishers.
Recent events (1)
  • — Z (S) $0

1910.219 D01

Serious Gravity 1 1 instance 8 exposed
Issued
Feb 29, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.219(d)(1) as required by 1960.8(b): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):  U.S. Geological Survey, Hammond Bay Biological Station, in the shop, the employer did not provide guarding around pulley on a 10 inch Craftsman Table Saw.  Pulley was located 26 inches from the floor there by exposing employees exposing employees to caught in hazards.
Recent events (1)
  • — Z (S) $0

1910.219 E03 I

Serious Gravity 1 1 instance 8 exposed
Issued
Feb 29, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(3)(i)as required by 1960.8(b): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o):   U.S. Geological Survey, Hammond Bay Biological Station, in the shop, the employer did not provide guarding around an incline belt on a 10 inch Craftsman Table Saw.   Incline belt was located 26 inches from the floor there by exposing employees exposing employees to caught in hazards.
Recent events (1)
  • — Z (S) $0

1910.305 B02 I

Serious Gravity 1 1 instance 8 exposed
Issued
Feb 29, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2)(i) as required by 1960.8(b): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:   In the raceway room, a junction box near the entrance door was missing protective cover and had wires protruding from the box exposing employees to an electrical hazard.
Recent events (1)
  • — Z (S) $0