BUFORD, GA ·
OSHA Inspection: SAUL MIRANDA
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SAUL MIRANDA in 1390 NEWBRIDGE CIR, BUFORD, GA 30518 (NAICS 238130). OSHA activity number 341194199.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SAUL MIRANDA
- Site address
- 1390 NEWBRIDGE CIR
- City
- BUFORD
- State
- GA
- ZIP
- 30518
- Mailing
- 1877 STURGEON RD, BUFORD, GA 30518
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 6
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1926.102 A01
- Issued
- Mar 7, 2016
- Abate by
- Mar 31, 2016
- Penalty
- Initial $1,600 · Current $960 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents. On or about January 12, 2016: a) Employees installing roof sheathing with pneumatic nail guns and hammers were exposed to eye injuries when the employer failed to ensure that they were wearing safety glasses while performing this task. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- · I (S) $960
- · Z (S) $1600
1926.403 B02
- Issued
- Mar 7, 2016
- Abate by
- Mar 31, 2016
- Penalty
- Initial $1,200 · Current $720 Reduced
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: On or about January 12, 2016 a) Employees were exposed to electrical shock and/or burns while utilizing a four way electrical outlet box to power various equipment, the four way electrical box is not designed to be used in this manner. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- · I (S) $720
- · Z (S) $1200
1926.501 B13
- Issued
- Mar 7, 2016
- Abate by
- Mar 31, 2016
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): On or about January 12, 2016: a) Employees installing roof sheathing were exposed to fall hazards of approximately 19.4 feet when the employer failed to ensure that employees were using fall protection measures to reduce or eliminate the fall hazard. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- · I (S) $1200
- · Z (S) $2000
More inspections in this industry (NAICS 238130)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341194199.