OSHA Inspection: METALDYNE SINTERFORGED PRODUCTS, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of METALDYNE SINTERFORGED PRODUCTS, LLC in 197 WEST CREEK ROAD, SAINT MARYS, PA 15857 (NAICS 332117). OSHA activity number 341194470.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Metaldyne Sinterforged Products, LLC — free Get an email when a new federal OSHA severe-injury report for Metaldyne Sinterforged Products, LLC is published. One employer, no account, unsubscribe in one click.
Site address
197 WEST CREEK ROAD
City
SAINT MARYS
State
PA
ZIP
15857
Mailing
197 WEST CREEK ROAD, SAINT MARYS, PA 15857
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332117
Employees
270
Ownership type
A

2 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 19, 2016
Abate by
Aug 12, 2016
Penalty
Initial $6,000 · Current $2,400 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by rotating parts:    a) Metaldyne Sinterforged Products, LLC, in St. Marys, PA, manual assembly area.  On or about January 19, 2016, and times prior thereto, the Powermatic drill press was not guarded to protect operators from the rotating head of the machine or parts.
Recent events (2)
  • — I (S) $2400
  • — Z (S) $6000

1910.212 A03 II

Serious Gravity 10 1 instance 3 exposed
Issued
Jul 19, 2016
Abate by
Aug 12, 2016
Penalty
Initial $7,000 · Current $6,000 Reduced
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposes an employee to injury, was not guarded:     a) Metaldyne Sinterforged Products, LLC, in St. Marys, PA, manual assembly area.  On or about January 19, 2016, and times prior thereto, the point of operation on the Shmidt Press was not guarded in that, the two hand controls were not designed, installed, and arranged to keep employees hands out of the point of operation during the machines operating cycle.
Recent events (2)
  • — I (S) $6000
  • — Z (S) $7000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341194470.