Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AUTO ELECTRONIC AMERICA, CORP

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of AUTO ELECTRONIC AMERICA, CORP in 3051 KUMHO PKWY, MACON, GA 31216 (NAICS 334417). OSHA activity number 341195790.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Auto Electronic America, Corp — free Get an email when a new federal OSHA severe-injury report for Auto Electronic America, Corp is published. One employer, no account, unsubscribe in one click.
Site address
3051 KUMHO PKWY
City
MACON
State
GA
ZIP
31216
Mailing
1040 FRICTION DR, PRATTVILLE, AL 36067
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
334417
Employees
10
Ownership type
A

4 citations on file for this inspection.

1926.350 A09

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 29, 2016
Abate by
May 25, 2016
Penalty
Initial $2,000 · Current $1,392 Reduced
29 CFR 1926.350(a)(9): Compressed gas cylinders were not secured in an upright position at all times:  On or about 12/15/15 located in the Process Building, CREEL area Room Vestibule -2: An Argo Compressed Acetylene cylinder was not secured in an position away from locations where they could be ran over by forklifts, pallet jacks and other moving equipment and employees.
Recent events (2)
  • — I (S) $1392
  • — Z (S) $2000

1926.453 B02 IV

Serious Gravity 10 1 instance 2 exposed
Issued
Apr 29, 2016
Abate by
May 25, 2016
Penalty
Initial $2,800 · Current $1,960 Reduced
29 CFR 1926.453(b)(2)(iv): Employee(s) working in an aerial lift were not standing firmly on the floor of the basket:   On or about 12/16/15 located in the Process Building, CREEL area Room Vestibule -2:  Two employees were climbing the rails / edge of the areal lift to get up in to the ceiling bar joist to install the plumbing and chill water lines onto the building at approximately 20- feet above the lower level and exposed to a fall hazard of up to 20.
Recent events (2)
  • — I (S) $1960
  • — Z (S) $2800

1926.1053 B01

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 29, 2016
Abate by
May 25, 2016
Penalty
Initial $2,800 · Current $1,960 Reduced
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:    On or about 12/16/15 located in the curing building pit area NW corner: An employee was exposed to fall hazards, while performing pipe work, the employee was using a job site made portable pipe extension ladder to gain access to the 1st floor, and the ladder was 8- inches below the landing surface.
Recent events (2)
  • — I (S) $1960
  • — Z (S) $2800

1926.1053 B16

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 29, 2016
Abate by
May 25, 2016
Penalty
Initial $2,800 · Current $1,960 Reduced
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired.    On or about 12/16/15 located in the curing building pit area NW corner: An employee was exposed to fall hazards, while performing pipe work, the employee was using a job site made portable pipe extension ladder to gain access to the 1st floor, with structural defect bending in the middle.
Recent events (2)
  • — I (S) $1960
  • — Z (S) $2800

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341195790.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.