TAMPA, FL ·
OSHA Inspection: COMRES MFG.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of COMRES MFG. in 7211 ANDERSON RD., TAMPA, FL 33634 (NAICS 332323). OSHA activity number 341198349.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COMRES MFG.
- Site address
- 7211 ANDERSON RD.
- City
- TAMPA
- State
- FL
- ZIP
- 33634
- Mailing
- 7211 ANDERSON RD., TAMPA, FL 33634
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332323
- Employees
- 17
- Ownership type
- Private (A)
Citations
6 citations on file for this inspection.
1910.23 C01
- Issued
- Feb 5, 2016
- Abate by
- Mar 24, 2016
- Penalty
- Initial $810 · Current $486 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent): (a) At the site - in the manufacturing area the mezzanine did not have guardrails exposing employees to a 12 foot fall when accessing this area, on or about 1/22/2016.
Recent events (2)
- · I (S) $486
- · Z (S) $810
1910.178 L01 I
- Issued
- Feb 5, 2016
- Abate by
- Jun 17, 2016
- Penalty
- Initial $1,200 · Current $720 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): (a) At the site - employees operating the Komatsu SN#10555 forklift were not trained, on or about 1/22/2016.
Recent events (2)
- · I (S) $720
- · Z (S) $1200
1910.178 P01
- Issued
- Feb 5, 2016
- Abate by
- Jun 17, 2016
- Penalty
- Initial $810 · Current $486 Reduced
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s): (a) At the site - the Komatsu SN#10555 forklift horn was inoperable and a seat belt was not provided, on or about 1/22/2016. (b) At the site - the Toyota forklift horn was inoperable and a seat belt was not provided, on or about 1/22/2016.
Recent events (2)
- · I (S) $486
- · Z (S) $810
1910.178 Q07
- Issued
- Feb 5, 2016
- Abate by
- Feb 18, 2016
- Penalty
- Initial $810 · Current $486 Reduced
General-duty citation text
29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed in service: (a) At the site - the Komatsu SN#10555 forklift was not inspected before each work shift to ensure the safety of the vehicle, on or about 1/22/2016. (b) At the site - the Toyota forklift horn was not inspected before each work shift to ensure the safety of the vehicle, on or about 1/22/2016.
Recent events (2)
- · I (S) $486
- · Z (S) $810
1910.305 B01 II
- Issued
- Feb 5, 2016
- Abate by
- Mar 24, 2016
- Penalty
- Initial $810 · Current $486 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: (a) At the site - in the manufacturing area the breaker box had unused openings, on or about 1/22/2016.
Recent events (2)
- · I (S) $486
- · Z (S) $810
1910.305 B02
- Issued
- Feb 5, 2016
- Abate by
- Mar 24, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(2): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: (a) At the site - in the manufacturing area the breaker box was not covered, on or about 1/22/2016. (b) At the site - in the manufacturing area the electrical outlet was not covered, on or about 1/22/2016.