OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Comres MFG. for free Get an email when a new federal OSHA severe-injury report for Comres MFG. is published. One employer, no account, unsubscribe in one click.
Establishment
COMRES MFG.
Site address
7211 ANDERSON RD.
City
TAMPA
State
FL
ZIP
33634
Mailing
7211 ANDERSON RD., TAMPA, FL 33634
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332323
Employees
17
Ownership type
Private (A)

6 citations on file for this inspection.

1910.23 C01

Serious Gravity 1 1 instance 1 exposed
Issued
Feb 5, 2016
Abate by
Mar 24, 2016
Penalty
Initial $810 · Current $486 Reduced
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent):  (a)  At the site - in the manufacturing area the mezzanine did not have guardrails exposing employees to a 12 foot fall when accessing this area, on or about 1/22/2016.
Recent events (2)
  • · I (S) $486
  • · Z (S) $810

1910.178 L01 I

Serious Gravity 1 1 instance 1 exposed
Issued
Feb 5, 2016
Abate by
Jun 17, 2016
Penalty
Initial $1,200 · Current $720 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):  (a)  At the site - employees operating the Komatsu SN#10555 forklift were not trained, on or about 1/22/2016.
Recent events (2)
  • · I (S) $720
  • · Z (S) $1200

1910.178 P01

Serious Gravity 1 2 instances 1 exposed
Issued
Feb 5, 2016
Abate by
Jun 17, 2016
Penalty
Initial $810 · Current $486 Reduced
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been  taken out of service until restored to safe operating condition(s):  (a)  At the site - the Komatsu SN#10555 forklift horn was inoperable and a seat belt was not provided, on or about 1/22/2016.  (b)  At the site - the Toyota forklift horn was inoperable and a seat belt was not provided, on or about 1/22/2016.
Recent events (2)
  • · I (S) $486
  • · Z (S) $810

1910.178 Q07

Serious Gravity 1 2 instances 1 exposed
Issued
Feb 5, 2016
Abate by
Feb 18, 2016
Penalty
Initial $810 · Current $486 Reduced
29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed in service:  (a)  At the site - the Komatsu SN#10555 forklift was not inspected before each work shift to ensure the safety of the vehicle, on or about 1/22/2016.  (b)  At the site - the Toyota forklift horn was not inspected before each work shift to ensure the safety of the vehicle, on or about 1/22/2016.
Recent events (2)
  • · I (S) $486
  • · Z (S) $810

1910.305 B01 II

Serious Gravity 1 1 instance 1 exposed
Issued
Feb 5, 2016
Abate by
Mar 24, 2016
Penalty
Initial $810 · Current $486 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  (a)  At the site - in the manufacturing area the breaker box had unused openings, on or about 1/22/2016.
Recent events (2)
  • · I (S) $486
  • · Z (S) $810

1910.305 B02

Serious Gravity 1 2 instances 1 exposed
Issued
Feb 5, 2016
Abate by
Mar 24, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:   (a)  At the site - in the manufacturing area the breaker box was not covered, on or about 1/22/2016.  (b)  At the site - in the manufacturing area the electrical outlet was not covered, on or about 1/22/2016.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0