Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: USGS-TRIGA REACTOR

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of USGS-TRIGA REACTOR in 6TH AVENUE & KIPLING STREET, BUILDING 15, LAKEWOOD, CO 80226 (NAICS 541712). OSHA activity number 341198653.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Usgs-Triga Reactor for free Get an email when a new federal OSHA severe-injury report for Usgs-Triga Reactor is published. One employer, no account, unsubscribe in one click.
Establishment
USGS-TRIGA REACTOR
Site address
6TH AVENUE & KIPLING STREET, BUILDING 15
City
LAKEWOOD
State
CO
ZIP
80226
Mailing
PO BOX 25046, MS 974, DENVER, CO 80225
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
541712
Employees
4
Ownership type
Federal government (D)

2 citations on file for this inspection.

1910.1025 H01

Serious Gravity 5 1 instance 3 exposed
Issued
Feb 24, 2016
Abate by
Mar 7, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.1025(h)(1):  All surfaces were not maintained as free as practicable of accumulations of lead:   1) On January 25, 2016, the surface directly outside of the fume hood in the lab was contaminated with lead at a level of approximately 103 ug/180cm2.
Recent events (1)
  • · Z (S) $0

1910.1200 F06 II

Other-than-serious 1 instance 3 exposed
Issued
Feb 24, 2016
Abate by
Mar 7, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(6)(ii):  The employer did not ensure that each container of hazardous chemicals was labeled with a product identifier and with general information regarding the hazards of the chemicals:    1) On January 25, 2016, and at prior times, a container of cadmium sheets located in the lab did not have a warning label concerning the hazards of the chemical.
Recent events (1)
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341198653.